Installation – Glow-worm Clearly Heat Pumps - Standalone System User Manual
Page 15

0020096321_01 - 02/11 - Glow-worm
- 13 -
4.2 Outdoor
sensor
1
Select Rmstat/sensor on
the screen.
2
Select Outdoor sensor on
the screen.
3
Select Connection on the
screen.
4
Press the button on the
outdoor sensor to connect.
b
The sensor is operational after 24h of exposure to
light and will therefore not function immediately after
being unpacked.
ON
1
Key
1 Outdoor sensor button
i
The External T°C Correction allows you to correct the
temperature measured by the outdoor sensor
(+/- 5 ° C, at intervals of 1 ° C - factory setting: 0).
5 Self
check
e
Do not modify the cables when connected to the mains.
The automatic test allows you to check EBUS inputs, NTC inputs,
the RF connection with the room thermostat, the outdoor sensor
radio connection.
i
The other connections are not tested and should be
visually inspected during installation or confi guration
modifi cations.
1
Select Self check on the
screen.
2
The automatic test will
start.
- If the connection is correct, the message "OK" appears
opposite the component.
- If the connection is not correct, the message "Not OK" appears
opposite the component.
In this case, check the connections (wired and wireless) .