Introduction, 6 - 2.5 hydraulic and refrigerant schematic – Glow-worm Clearly Heat Pumps Envirosorb2 User Manual
Page 8
0020117819_00 - 01/11 - Glow-worm
- 6 -
2.5
Hydraulic and refrigerant schematic
9
10
11
12
14
15
16
17
19
20
22
23
21
18
24
1
3
2
4
5
6
7
A
C
13
8
B
Key
1 fan (1 fan for the 7 kW model, 2 fans for the 12 and 15 kW models)
2 Air input temperature sensor
3 Tubular heat exchanger
4 Temperature sensor for the tubular heat exchanger
5 4-way cycle inversion gate
6 Temperature sensor for compressor suction
7 Silencer
8 Expansion vessel (in this position for the 8 kW model)
9 Automatic purge vent for the heat pump circuit
10 Water flow detector for the heat pump circuit
11 Circulator for the heat pump circuit
12 Safety valve for the heat pump circuit
13 Expansion vessel (in this position for the 12 and 15 kW models)
14 flow temperature sensor for the heat pump
15 Return temperature sensor for the heat pump
16 Draining valve for the heat pump circuit
17 Plate to plate exchanger
18 Pre-expansion temperature sensor
19 Anti-slugging bottle
20 Rotary compressor
21 Liquid tank
22 Silencer
23 Compressor discharge temperature sensor
24 Electronic expansion unit
A Heat pump return
b Heat pump flow
C Evacuation from the safety valve to a container for recovering glycol
water