TECHNICAL DATA
i
This technical data is valid for a new appliance with its
own heat exchangers.
6 Envirosorb
Description
Unit
7
12
14
Min. operating outside temperature (in heating)
°C
-20
-20
-20
Max. operating outside temperature (in heating)
°C
30
30
30
Specifications, with radiators
(flow : 45°C, return : 40°C, outside dry temperature (wet) 7 (6)°C)
Heating output
kW
7.4
12.9
14
Power input
kW
2.32
4.2
4.4
Rated electrical current
A
10
18.5
19
COP* A7(6) W45-40
3.18
3.03
3.21
Specifications, with underfloor heating
(flow : 35°C, return : 30°C, outside dry temperature (wet) : 7 (6)°C)
Heating output
kW
7.2
11.9
14.5
Power input
kW
1.82
3.01
3.6
Rated electrical current
A
8
13
15.6
COP* A7(6) W35-30
3.96
3.94
4.06
Refrigerant circuit
Type of refrigerant
Quantity of refrigerant
kg
1.81
2.485
3.385
Type of compressor
Rotary
Type of oil
Polyolester
Type of regulator
Electronic
Fan speed
rpm
1000
805
1050
Maximum operating pressure (PS)
bar
45
45
45
Pa
45 x 10
5
45 x 10
5
45 x 10
5
Heat pump circuit
Max. supply pressure.
bar
3
3
3
Pa
3 x 10
5
3 x 10
5
3 x 10
5
Nominal static pressure
bar
0.4
0.45
0.3
Pa
40 x 10
3
45 x 10
3
30 x 10
3
Nominal water flow rate in heating mode
l/h
1200
2100
2500
Minimum water flow rate
l/h
500
500
500
Minimum flow temperature setting (in heating)
°C
20
20
20
Maximum flow temperature setting (in heating)
°C
60
60
60
Heat pump water volume
l
1.2
2.3
2.3