beautypg.com

Technical data, 6 envirosorb – Glow-worm Clearly Heat Pumps Envirosorb2 User Manual

Page 12

background image

0020117819_00 - 01/11 - Glow-worm

- 10 -

TECHNICAL DATA

i

This technical data is valid for a new appliance with its

own heat exchangers.

6 Envirosorb

Description

Unit

7

12

14

Min. operating outside temperature (in heating)

°C

-20

-20

-20

Max. operating outside temperature (in heating)

°C

30

30

30

Specifications, with radiators
(flow : 45°C, return : 40°C, outside dry temperature (wet) 7 (6)°C)
Heating output

kW

7.4

12.9

14

Power input

kW

2.32

4.2

4.4

Rated electrical current

A

10

18.5

19

COP* A7(6) W45-40

3.18

3.03

3.21

Specifications, with underfloor heating
(flow : 35°C, return : 30°C, outside dry temperature (wet) : 7 (6)°C)
Heating output

kW

7.2

11.9

14.5

Power input

kW

1.82

3.01

3.6

Rated electrical current

A

8

13

15.6

COP* A7(6) W35-30

3.96

3.94

4.06

Refrigerant circuit
Type of refrigerant
Quantity of refrigerant

kg

1.81

2.485

3.385

Type of compressor

Rotary

Type of oil

Polyolester

Type of regulator

Electronic

Fan speed

rpm

1000

805

1050

Maximum operating pressure (PS)

bar

45

45

45

Pa

45 x 10

5

45 x 10

5

45 x 10

5

Heat pump circuit

Max. supply pressure.

bar

3

3

3

Pa

3 x 10

5

3 x 10

5

3 x 10

5

Nominal static pressure

bar

0.4

0.45

0.3

Pa

40 x 10

3

45 x 10

3

30 x 10

3

Nominal water flow rate in heating mode

l/h

1200

2100

2500

Minimum water flow rate

l/h

500

500

500

Minimum flow temperature setting (in heating)

°C

20

20

20

Maximum flow temperature setting (in heating)

°C

60

60

60

Heat pump water volume

l

1.2

2.3

2.3

TECHNICAl DATA