Installation – Glow-worm Clearly Heat Pumps Envirosorb2 User Manual
Page 30

0020117819_00 - 01/11 - Glow-worm
- 28 -
Envirosorb 8 flow/pressure curves
A
B
200
400
600
800
0
10
20
30
40
50
60
1
2
3
Key
1 Speed I
2 Speed II
3 Speed III
A Available pressure (kPa)
b flow in the circuit (l/h)
Envirosorb 12, Envirosorb 15 flow/pressure curves
A
B
200
400
600
800
0
10
20
30
40
50
60
70
80
1
2
3
Key
1 Speed I
2 Speed II
3 Speed III
A Available pressure (kPa)
b flow in the circuit (l/h)
15.2 Settings for the command unit
15.2.1
Appliance configuration parameters
i
If the parameters are changed, it is important to leave
the control box connected for at least 10 seconds so
that the change is properly saved.
• Press simultaneously on the button ( ) and (M) for 3
seconds. The parameter number is displayed and its value
blinks.
• Press the buttons (M) and ( ) to access the parameter "302".
The value of the parameter flashes.
Description of parameter 302
Setting
factory
setting
Min
Max
0 = Cooling only
1 = Heating + cooling
2 = Heating only
0
2
2
• Press the buttons (
) to modify the value.
• Press the button (M) or (OK) to confirm the parameter setting.
i
The other parameters 301, 303, 304, 305 and 306
must not be modified.
• Press the button (OK) to exit the menu and validate the
settings.
INSTAllATION