Sk350 operator’s manual – Ditch Witch SK350 User Manual
Page 64

SK350 Operator’s Manual
Service - 63
As Needed
CMW
5.
Pull tensioner back and slip belt off of the idler
pulley.
6.
Remove belt from pulleys and carefully work it
around fan and through the fan hole.
7.
Remove belt through opening.
8.
Install new belt in reverse order of removal and
position tensioners to contact belt.
9.
Adjust belt tension. See page 55 for belt adjustment
procedure.
10. Start engine and check operation.
11. Stop engine, open hood, and re-check belt alignment.
12. Close hood.
Moving parts could cut off hand or foot. Stay away.
NOTICE: Do not open hood for inspection or service with engine running.
Runaway possible. Machine could run over you or others. Learn how to
use all controls. Start and operate only from operator’s position.
NOTICE: Do not leave operator station with engine running.
- JT5 (161 pages)
- JT922 (159 pages)
- JT9 (165 pages)
- JT20 (195 pages)
- JT1220 (201 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- FM25 (67 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX20 (100 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- MV800 (111 pages)
- RT Line (115 pages)
- RT30 (97 pages)
- RT45 (203 pages)
- RT55 (177 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK750/SK755 (81 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)