Service - 52
SK350 Operator’s Manual
10 Hour
CMW
Check Hydraulic Fluid Level
Check hydraulic fluid level every 10 hours. Maintain fluid level at halfway point on sight glass (1), when
engine is off and fluid is cool. If low, add THF at fill (2).
Check Track Tension
Check track tension every 10 hours and adjust as needed. Turn bolt (1) clockwise to tighten and
counterclockwise to loosen. Track tension is correct when dimension A is 8 5/8” (219 mm) ±.250” (6.4
mm).
IMPORTANT: Dimension A is the overall spring length, compressed.