FX30/FXT30 Operator’s Manual
Controls - 37
Machine Controls
CMW
®
Item
Description
Notes
1.
Inlet valve
To close valve (stop suction),
rotate up.
To open valve (start suction),
rotate down.
NOTICE: Do not idle engine with inlet
valve closed.
2.
Water tank supply valve
To open valve (send water
from the water tank through
the pump and water lance),
rotate counterclockwise.
To close valve (stop water
flow), rotate clockwise.
IMPORTANT: Water tank supply
valve or antifreeze supply valve must
be open when pump is running or
pump will be damaged.
3.
Water tank drain
To drain tank, open valve.
Close valve when tank is
empty.
4.
Drain/Outlet valve
To drain tank, rotate down.
To close drain, rotate up.