100 hour, Fm25 operator’s manual – Ditch Witch FM25 User Manual
Page 53
Service - 52
FM25 Operator’s Manual
100 Hour
CMW
100 Hour
Change Fuel Filters
Change fuel filter (1) and inline fuel filter (2) every
100 hours.
1.
Remove filters.
2.
Fill new filter with clean fuel.
3.
Apply fuel oil over the gasket and hand-tighten.
Check Fan Belt Tension
Check pump drive belt tension every 100 hours.
1.
Turn off engine and remove key.
2.
Apply moderate thumb pressure to top of belt.
Belt is properly tensioned when deflection (A)
is 1/4-1/2” (5-13 mm). To adjust, see page 56.
Location
Task
Notes
Change fuel filters
Check fan belt tension
See also other documents in the category Ditch Witch Special machinery:
- JT5 (161 pages)
- JT922 (159 pages)
- JT9 (165 pages)
- JT20 (195 pages)
- JT1220 (201 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX20 (100 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- MV800 (111 pages)
- RT Line (115 pages)
- RT30 (97 pages)
- RT45 (203 pages)
- RT55 (177 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK350 (77 pages)
- SK750/SK755 (81 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)