Input 1: Voltage detected on this input will cause DownMix to go into pass-though operating
mode.
Input 2: Voltage detected on this input will have DownMix take the input audio signal and down-
mix into Lt/Rt.
Input 3: Unused at this time.
Input 4: Unused at this time.
NETWORK - Used to update DownMix’s firmware. To connect directly to a PC without use of a network
switch or hub, a crossover cable is required. Firmware updating is accomplished via UDP Port 44600.
PSU 1 / PSU 2 - Two IEC320 ports to connect to AC Mains. The internal power supplies are auto
switching and will work on 120VAC-60Hz or 240VAC-50Hz electrical power systems with a maximum
total current draw of 25W (>.25A 120VAC or >.15A 240VAC).
Please connect DownMix to a properly grounded uninterruptible power supply (UPS) to protect
against power surges and low-voltage conditions. For maximum redundancy, connect each power
supply to a separate UPS on different power circuits. DownMix may be combined with other devices on
the output of the UPS(es) as long as the total load is within the UPS’ capacity. Consult your UPS
manual for details.