Alarm sending

Set to send the mail with connection to the alarm detection by the external sensor input or by the built-in

motion detection function.


Alarm sending:Select On to set to send mail with connection to the alarm detection.

File attachment:Set whether an image file is attached to the mail sent or not. When On is selected, the

image file made by the settings below is attached. When Off is selected, only the message is sent.
Image file name:Type the file name you want to assign to the image to attach a mail. You can use up to 10

alphanumeric, - (hyphen) and _ (underscore) for naming.
Suffix:Select a suffix to add to the file name:

None: No suffix is added. The Image file name is assigned to the image to be sent via an e-Mail.

Date & time: The date & time suffix is added to the Image file name. The date/time suffix consists of lower

two-digits of year (2 digits), month (2 digits), date (2 digits), hour (2 digits), minute (2 digits), second (2

digits), and consecutive number (2 digits), thus 14-digit number is added to the file name.

Sequence number: A consecutive number of 10 digits between 0000000001 and 4294967295 and two

fixed digits 00 is added to the Image file name.
Motion Detection:Click it on for using Motion Detection function as a sensor. You can set the motion

detection function page.
Note:

• Motion Detection works only when the Video mode is set to MPEG4 and the Cropping is set to Off.
Alarm Buffer:Select Use alarm buffer when you forward the image/ audio of before and after the alarm

detection (pre-alarm, post-alarm). If you do not select it, only the image of the moment of the alarm