Avalue EPI-LX800 User Manual
Page 68
EPI-LX800 Series
68 EPI-LX800 Series User’s Manual
3.5.3.5 Flat
Panel
Configuration
Item
Options
Description
Flat Panel Type
TFT, LVDS
Auto
This item allows to select the flat panel
type.
Resolution
320x240, 640x480
800x600, 1024x768,
1152x864, 1280x1024
1600x1200
This item allows to select the
resolution of display.
Data Bus Type
9-24 bits, 1 ppc
18,24 bits, 2ppc
This item allows to select the display
data bus type.
Refresh Rate
60Hz, 70Hz,72Hz
75Hz, 85Hz, 90Hz
100Hz
This refresh rate is only the number of
time the image is being refreshed on
the monitor screen.
HSYNC Polarity
High, Low
Select polarity of HSYNC signals.
VSYNC Polarity Active
High, Low
Set the polarity of VSYNC signals
active.
SHFCLK Active Period
Active only,
Free running
Shift clock or pixel clock for the flat
panel data.
LP Active Period
Active running
Free running
Latch Pulse is the line pulse or latch
pulse for the flat panel data.
3.5.3.6 Onboard
Audio
This item allows you to enable the onboard audio function.
The choices: Enabled, Disabled.
3.5.3.7 Memory Hole at 15M-16M
You can reserve this area of system memory for ISA adapter ROM. When this area is
reserved it cannot be cached. The user information of peripherals that need to use this area
of system memory usually2 discussed their memory requirements.
The choices: Enabled, Disabled.