Danger, En english, Machine set-up – American Sanders CE7 & Pro Edgers User Manual
Page 9
EN
ENGLISH
Clarke
®
American Sanders
Operator's Manual (EN) - CE7 Pro, SE7 Pro, CE7 Pro+, SE7 Pro+ - 9 -
Figure 4.1
Figure 4.2
Figure 5.1
MACHINE SET-UP
Fig. 4.1 Electrical Connection
The unit is equipped with a grounding NEMA L5-15P locking plug (fig
4.1). Connection to an electrical source is made through an extension
cord (optional 42300A). Connect the plug on the extension cord
to a wall outlet matching one of the two shown (fig. 4.2). Plug the
appliance into the matching connector then twist clockwise until the
cables are locked.
NOTE: The extension cord must be sized to a minimum of 14 AWG 2
conductor with ground not exceeding 50’ in length and have for ends
a NEMA 5-15P plug and NEMA L5-15R connector. An extension cord
sized smaller than 14 AWG or greater than 50’ in length will overheat
and potentially cause a fire.
DANGER!
This appliance must be grounded. Should an electrical malfunction
occur, the grounding conductor provides a path to harmful charge.
Do not connect this appliance to any other wall outlet than one of
those shown in fig. 4.2. Consult an electrician if there is reason to
doubt that the wall outlet is not wired correctly. Do not remove pin on
the extension cord. Do not use the appliance with a damaged cord or
connectors.
Fig. 5.1 Controls
All controls are conveniently located on the handle providing comfort
and security. The master control switch (all models) is activated with
a rocking motion as shown in figure 5.1a. The switch will remain
activated until it is deliberately deactivated or if there is a loss of
power. The speed control switch (models 07170A and 07176A only)
varies the abrasive disc speed (fig. 5.1b). The switch is operated with
a rocking motion. The switch will remain in a particular setting until it
is deliberately changed.
A
B
LOW HIGH
OFF ON