Environmental specifications, Table 3, System power requirements (littleboard 800) – ADLINK RuffSystem 800 User Manual
Page 8: Table 4, Environmental requirements

RuffSystem Setup
4
User’s Guide
RuffSystem
lists the current draw values of the RuffSystem with the LittleBoard 800.
Operating configurations:
•
In-rush operating configuration includes one LittleBoard 800, 1GB DDR RAM, AMI BIOS, I/O board,
AC/DC external digital power supply, DC/DC internal power module, CRT monitor, HDD, keyboard
and mouse.
•
Idle operating configuration includes the same items as the In-rush configuration.
•
BIT* = Burn-In-Test. Operating configuration includes Idle configuration as well as four serial loop
backs, one parallel port with loop back, two Ethernet connections, four external USB flash drives, and
one Compact Flash card.
Environmental Specifications
provides the most efficient operating and storage condition ranges required for this system with the
LittleBoard 735, LittleBoard 800, and COM 840.
Table 3. System Power Requirements (LittleBoard 800, 1.4 GHz Pentium M CPU)
Input Type
In-rush Current
(@ 170.88W Power)
Typical Idle Current
(@ 9.54W Power)
Typical BIT* Current
(@ 13.18W Power)
+14VDC
12.21A
0.68A
0.94A
+16VDC
10.68A
0.60A
0.82A
+18VDC
9.49A
0.53A
0.73A
+20VDC
8.54A
0.48A
0.66A
+22VDC
7.77A
0.43A
0.60A
+24VDC
7.12A
0.40A
0.55A
+26VDC
6.57A
0.37A
0.51A
+28VDC
6.10A
0.34A
0.47A
+30VDC
5.70A
0.32A
0.44A
+32VDC
5.34A
0.30A
0.41A
NOTE
Extended temperature range available only on extended temperature tested
(ETT) systems.
Table 4. Environmental Requirements
Temperature
Humidity
Operating
Storage
Extended
Operating
Non-operating
-20
° to +65°C
(-4
° to +149°F)
–55° to +85°C
(–67° to +185°F)
–40° to +75°C
(–40° to +167°F)
5% to 90%
relative humidity,
non-condensing
5% to 95%
relative humidity,
non-condensing