ADLINK MXE-200i User Manual
Page 49
Watchdog Timer (WDT) & DI/O Function Libraries
35
MXE-200
BOOL StartWDT()
@ Parameters
None
@ Return codes
TRUE
if watchdog timer is successfully started.
FALSE
if watchdog timer is failed to start.
ResetWDT
Resets the watchdog timer. The invocation of ResetWDT
allows restoration of the watchdog timer to the initial timeout
value specified in SetWDT function. ResetWDT or StopWDT
should be called before the expiration of the watchdog timer, or
the system will reset.
@ Syntax
C/C++
BOOL ResetWDT()
@ Parameters
None
@ Return codes
TRUE
if watchdog timer is successfully reset.
FALSE
if watchdog timer fails to reset.
StopWDT
Stops the watchdog timer.
@ Syntax
C/C++
BOOL StopWDT()
@ Parameters
None
@ Return codes
TRUE
if watchdog timer is successfully stopped.