ADLINK MXE-200i User Manual
Page 18
4
Introduction
Extended Temperature
-20°C to 60°C
(w/ industrial mSATA)
-20°C to 70°C
(w/ industrial mSATA)
Storage Temperature
-40°C to 85°C (excl. HDD/SDD/CFAST)
Humidity
~95% @ 40°C (non-condensing)
Vibration
Operating, 5 Grms, 5-500 Hz, 3 axes (w/ mSATA)
ESD
Contact +/-4 KV and Air +/-8 KV
Shock
Operating, 50 G, half sine 11 ms duration (w/
mSATA)
EMC
CE and FCC Class A
Safety
UL, CB
NOTE:
NOTE:
Cold boot of the system at -20°c and operation with 100% load-
ing at 60°c is provided when the industrial solid-state drive stor-
age option is implemented.
Power Consumption
Power off
0.3W
In shutdown mode with DC input and
only USB keyboard/mouse
System Idle
6.3W
Under Windows Desktop with no
application programs executed
Processor full load
12.5W
Under Windows with 100% CPU
utilization and 2D/3D graphics load
System full load
22W
Under Windows with 100% CPU
utilization and simultaneous access to
all I/O devices
Recommended power
supply
40W
With consideration of voltage de-rating
under high environmental temperature
MXE-201
MXE-202