Interface signals, 5 interface signals – ADLINK LEC-3517 User Manual
Page 9
Overview
5
LEC-3517
Environmental Specifications
Table 1-5 provides the most efficient operating and storage condition ranges required for this
module.
Thermal/Cooling Requirements
The LEC-3517 is designed to operate at its maximum CPU speed and requires a thermal solu-
tion. ADLINK offers one optional thermal solution described in Table 1-6.
1.5 Interface Signals
Table 1-7 provides the pin signals for the SMARC P-S connector. Refer to the SMARC specifica-
tion at
http://www.sget.org/standards/smarc.html
for definitions of the SMARC signals.
Table 1-5: Environmental Requirements
Parameter
Conditions
Temperature
Standard
–20° to +70° C (-4° to +158° F)
Extended (Optional)
–40° to +85° C (–40° to +185° F)
Storage
–55° to +85° C (–67° to +185° F)
Humidity
Operating
5% to 90% relative humidity, non-condensing
Non-operating
5% to 95% relative humidity, non-condensing
The overall system design must keep the ICs within their operating temperature
specifications.
Table 1-6: ADLINK Optional Cooling Solutions
Cooling Solution
Description
Passive Heatsink
(without fan)
Qualified to maintain optimal performance up to +85°C. (See Quick Start
Guide for P/N of heatsink.)
Table 1-7: SMARC P-S Connector Signal Descriptions
Pin #
Primary (Top Side)
Pin #
Secondary (Bottom Side)
S1
PCAM_VSYNC
P1
Not connected
S2
PCAM_HSYNC
P2
GND
S3
GND
P3
CSI1_CK+/PCAM_D0
S4
PCAM_PXL_CK0
P4
CSI1_CK-/PCAM_D1
S5
I2C_CAM_CK
P5
Not connected
S6
CAM_MCK
P6
PCAM_MCK
S7
I2C_CAM_DAT
P7
CSI1_D0+/PCAM_D2
S8
Not connected
P8
CSI1_D0-/PCAM_D3
S9
Not connected
P9
GND
S10
GND
P10
CSI1_D1+/PCAM_D4
S11
Not connected
P11
CSI1_D1-/PCAM_D5
S12
Not connected
P12
GND
S13
GND
P13
CSI1_D2+/PCAM_D6
S14
Not connected
P14
CSI1_D2-/PCAM_D7
S15
Not connected
P15
GND
S16
GND
P16
Not connected
S17
Not connected
P17
Not connected
S18
Not connected
P18
GND
S19
Not connected