SDVO from Module to Flat Cable connector CN30

Since COM Express Type 1 and Type 10 only define the AB connector, the CD connector which
brings out SDVO signals from COM Express Type 2~6 modules to the carrier is not available.
The method described below for connecting SDVO signals from the module to the carrier allows
the nanoX-BASE to be compatible with both Type 1 and Type 10 modules.

Type 1

The SDVO signals on a Type 1 module (e.g. nanoX-ML) are brought out through a Hirose FH12-
30S-0.5SH(55), 30-pin FFC/FPC connector on the module. Connect the SDVO signal from the
output connector on the Type 1 module to CN30 on the nanoX-BASE carrier board using the flat
ribbon cable provided.

Maximum routing length from connector to SDVO device is approximately 6”, so a cable

length of up to 4” can be used.

Type 10

The SDVO signals on a Type 10 module (e.g. nanoX-TC) are brought out through the AB
connector to a Hirose FH12-30S-0.5SH(55), 30-pin FFC/FPC connector on the carrier (CNX5).
Connect the SDVO signal from the CNX5 output connector to CN30 on the nanoX-BASE carrier
board using the flat ribbon cable provided.

30

1

CN30

Flat cable

Type 1 Module

CN30

Type 10 Module

CNX5

30

1

Flat cable