beautypg.com

ADLINK ND-6054 User Manual

Page 71

background image

Command Set

63

Note : When you want to change the checksum or baud rate then the

DEFAULT* pin should be grounded at first.

@Example

User command:

%0130400600

Response:

!30

Item Meaning

Description

%

(Leading Code)

Command leading code.

01

(OldAddr)

Original address ID is 01H.

30 (NewAddr)

New address ID is 30H
(Hexadecimal).

40

(TypeCode)

Digital I/O module.

06

(BaudRate)

Baud rate is 9600.

00

(CheckSumFlag)

00 means checksum is disable.

Carriage

return 0x0D.

Code

Baudrate

03 1200

bps

04 2400

bps

05 4800

bps

06 9600

bps

07 19200

bps

08 38400

bps

09 115200

bps

Table 0-1 Baud rate setting code

Table 0-2 Check sum flag setting

7

6

5

4

3

2

1

0

Reserved
Must to be 0

Checksum
0 : disable
1 : enable

Reserved
Must to be 000000