ADLINK ND-6054 User Manual
Page 66
58
• Command Set
3.1.2 Document
Conventions
The following syntax conventions are used to describe the NuDAM
commands in this manual.
(Leading
Code)
Leading Code is the first characteristic of the NuDAM
command. All NuDAM commands need a command
leading code, such as %,$,#,@,...etc.
1- character
(Addr)
Module’s address ID, the value is in the range of 00 - FF
(Hexadecimal) if no specified in the following
2- character
(Comman
d
Variable)
Items indicate command codes or value of variables
Variable length
[Data]
Some output command need data
Variable length
[Checksu
m]
Checksum in brackets indicate optional parameter,
only checksum is enable then this field is required
2- character
< >
Identifies a control code character, such as
carriage return, its value is 0x0D. 1- character
3.1.3 Format of NuDAM Commands
(Leading Code)(Addr)(Command)[Data][Checksum]
When checksum is enable then [Checksum] is needed, it is
2-character.
How to calculate checksum value ?
[Checksum] = ((LeadingCode)+(Addr)+(Command)+[Data]) MOD 0x100
Example 1: checksum is disable
User Command: $012
Response: !01400600
$ :
LeadingCode
01 :
Address
2 : Command (Read Configuration)