ADLINK PXIS-2508 User Manual
Page 46

36
Remote Management
BYTE
Reserve1;
BYTE
Reserve2;
} ChassisStatus;
The variables in the data structure are illustrated below.
Variable
Description
Type
Value
PowerStatus
Power On/Off status
BYTE
0: Off
1: On
Fan1Status
Fan#1 operating status
BYTE
0: Normal
1: Abnormal
Fan2Status
Fan#2 operating status
BYTE
0: Normal
1: Abnormal
Fan3Status
Not used for PXIS-2508/2558T
BYTE
N/A
Fan4Status
Not used for PXIS-2508/2558T
BYTE
N/A
Fan5Status
Not used for PXIS-2508/2558T
BYTE
N/A
Fan6Status
Not used for PXIS-2508/2558T
BYTE
N/A
Fan1RPM
Fan#1 speed in RPM
float
RPM value
Fan2RPM
Fan#2 speed in RPM
float
RPM value
Fan3RPM
Not used for PXIS-2508/2558T
float
N/A
Fan4RPM
Not used for PXIS-2508/2558T
float
N/A
Fan5RPM
Not used for PXIS-2508/2558T
float
N/A
Fan5RPM
Not used for PXIS-2508/2558T
float
N/A
Temp1Status
Temperature sensor#1 status
BYTE
0: Normal
1: Abnormal
Temp2Status
Temperature sensor#1 status
BYTE
0: Normal
1: Abnormal
Temp1Reading
Reading of temperature sensor#1 in °C float
Temperature value
Temp1Reading
Reading of temperature sensor#2 in °C float
Temperature value
DC1Status
DC 12V status
BYTE
0: Normal
1: Abnormal
DC2Status
DC 5V status
BYTE
0: Normal
1: Abnormal
DC3Status
DC 3.3V status
BYTE
0: Normal
1: Abnormal
DC4Status
DC -12V status
BYTE
0: Normal
1: Abnormal
DC1Reading
DC 12V voltage reading
float
Voltage value
DC2Reading
DC 5V voltage reading
float
Voltage value
DC3Reading
DC 3.3V voltage reading
float
Voltage value