beautypg.com

J8: extra general purpose i/o (optional), Pin # symbol function description – Delta Tau 5xx-603869-xUxx User Manual

Page 29

background image

Brick Motion Controller Hardware Reference Manual

System Wiring

21

J8: Extra General Purpose I/O (Optional)

General purpose I/O is available on the Brick Motion Controller. All I/O is electrically isolated from the
drive. Inputs can be configured for sinking or sourcing applications. All Inputs are 12-24VDC. All
Outputs are 24V nominal operation, 0.5A maximum current. Outputs are robust against ESD and
overload.

J8 General Purpose I/O

(Female DB-37 Connector)

36

33

1

20

2

3

4

5

9

10

28

27

26

25

24

21

22

23

11

8

7

6

29

30

32

16

15

14

13

12

17

18

19

31

34

35

37

Pin #

Symbol

Function

Description

1 GPIN33 Input

Input

33

2 GPIN35 Input

Input

35

3 GPIN37 Input

Input

37

4 GPIN39 Input

Input

39

5 GPIN41 Input

Input

41

6 GPIN43 Input

Input

43

7 GPIN45 Input

Input

45

8 GPIN47 Input

Input

47

9

IN_COM 33-40

Input

Input 33 to 40 Common

10 N.C

Not

Connected

11

COM_EMT

Input

Common Emitter *

12

GP17-

Output

Sourcing Output 17 **

13

GP18-

Output

Sourcing Output 18 **

14

GP19-

Output

Sourcing Output 19 **

15

GP20-

Output

Sourcing Output 20 **

16

GP21-

Output

Sourcing Output 21 **

17

GP22-

Output

Sourcing Output 22 **

18

GP23-

Output

Sourcing Output 23 **

19

GP24-

Output

Sourcing Output 24 **

20 GPIN34 Input

Input

34

21 GPIN36 Input

Input

36

22 GPIN38 Input

Input

38

23 GPIN40 Input

Input

40

24 GPIN42 Input

Input

42

25 GPIN44 Input

Input

44

26 GPIN46 Input

Input

46

27 GPIN48 Input

Input

48

28

IN_COM_41-48

Input

Input 41 to 48 Common

29 COM_COL Input

Common Collector **

30

GP17+

Output

Sinking Output 17 *

31

GP18+

Output

Sinking Output 18 *

32

GP19+

Output

Sinking Output 19 *

33

GP20+

Output

Sinking Output 20 *

34

GP05+

Output

Sinking Output 21 *

35

GP22+

Output

Sinking Output 22 *

36

GP23+

Output

Sinking Output 23 *

37

GP24+

Output

Sinking Output 24 *

*For sinking outputs, connect the COM_EMT (pin11) line to the Analog Ground of the Power supply and the outputs to
the individual plus output lines, e.g. GPO1+
**For sourcing outputs, connect the COM_COL (pin29) line to 12-24V and the outputs to the individual minus output
lines, e.g., GPO1-
Do not mix topologies, i.e., all sinking or all sourcing outputs. If the common emitter is used, the common collector
should be unconnected. Conversely, if the common collector is used, the common emitter should be unconnected.