Brick Motion Controller Hardware Reference Manual
2
Introduction
•
Primary encoder for each axis with TTL differential/single-ended inputs with A, B quadrature
channels and C index channel, 10 MHz cycle rate, and digital Hall-effect inputs
•
Five flags per axis using DB-25: HOME, PLIM, MLIM and USER inputs; EQU compare
•
Optional analog inputs and outputs, ± 5VDC
•
Optional two PWM outputs.
•
Optional Dual Port RAM (Required for NC)
•
Optional Modbus Protocol
•
Optional Sinusoidal encoder feedback
•
Optional Resolver feedback
•
Optional EnDat, Hiperface interfaces.