Brick Motion Controller Hardware Reference Manual

2

Introduction

Primary encoder for each axis with TTL differential/single-ended inputs with A, B quadrature
channels and C index channel, 10 MHz cycle rate, and digital Hall-effect inputs

Five flags per axis using DB-25: HOME, PLIM, MLIM and USER inputs; EQU compare

Optional analog inputs and outputs, ± 5VDC

Optional two PWM outputs.

Optional Dual Port RAM (Required for NC)

Optional Modbus Protocol

Optional Sinusoidal encoder feedback

Optional Resolver feedback

Optional EnDat, Hiperface interfaces.