CANpro/104 User Manual


CTIM-00043 (0.01) 1/15/2010

www.connecttech.com

12

800-426-8979 | 519-836-1291

CAN Controller Addressing Table

Once the Base Memory or I/O Address is setup, the 2 SJA1000 CAN controllers are accessed at the
following address offsets.

Accessed Resource

Offset from Base Address

Memory Space

I/O Space

BasicCAN mode

PeliCAN mode

CAN-0 Port (SJA1000)

0x000  0x07F

0x000  0x01F

0x000  0x07F

CAN-1 Port (SJA1000)

0x080  0x0FF

0x020  0x03F

0x080  0x0FF

Memory Enable Bit

At the I/O Address setup

with JB3 Positions 5,6,7

N/A

N/A

Table 12

The SJA1000 Register offsets can be found in the documentation from NXP Semiconductor
(formerly Philips).

www.nxp.com

(enter SJA1000 into their search tool).