beautypg.com

Connect Tech CANPRO CTIM-00043 User Manual

Page 11

background image

CANpro/104 User Manual


11

www.connecttech.com

CTIM-00043 (0.01) 1/15/2010

800-426-8979 | 519-836-1291

Example #2:

Memory Address 0x0C8000 (this address is below the 1-Meg boundary)
0x0C8000 =

0000.1100.100

X.XXXX.CJJJ.JJJJ (binary)

Address

Bit

Bit

Value

J3A or J3B

Position

Installed

or Removed

23

0

J3A-2

Removed

22

0

J3A-3

Removed

21

0

Address Bit always decoded as “0”

20

0

Address Bit always decoded as “0”

19

1

J3A-4

Installed

18

1

J3A-5

Installed

17

0

J3A-6

Removed

16

0

J3B-1

Removed

15

1

J3B-2

Installed

14

0

J3B-3

Removed

13

0

J3B-4

Removed

Table 9


Example #3:

I/O Address 0x340 (BasicCAN mode)
0x340 = XXXX.XXXX.XXXX.X

011.01

CJ.JJJJ (binary)

Address

Bit

Bit

Value

J3A or J3B

Position

Installed

or Removed

23 -> 11

X

---

---

10

0

J3A-6

Removed

9

1

J3B-1

Installed

8

1

J3B-2

Installed

7

0

J3B-3

Removed

6

1

J3B-4

Installed

Table 10

Example #4:

I/O Address 0x600 (PeliCAN mode)
0x600 = XXXX.XXXX.XXXX.X

110.

CJJJ.JJJJ (binary)

Address

Bit

Bit

Value

J3A or J3B

Position

Installed

or Removed

23 -> 11

X

---

---

10

1

J3A-6

Installed

9

1

J3B-1

Installed

8

0

J3B-2

Removed

Table 11