Connect Tech CANPRO CTIM-00043 User Manual
Page 11
CANpro/104 User Manual
11
www.connecttech.com
CTIM-00043 (0.01) 1/15/2010
800-426-8979 | 519-836-1291
Example #2:
Memory Address 0x0C8000 (this address is below the 1-Meg boundary)
0x0C8000 =
0000.1100.100
X.XXXX.CJJJ.JJJJ (binary)
Address
Bit
Bit
Value
J3A or J3B
Position
Installed
or Removed
23
0
J3A-2
Removed
22
0
J3A-3
Removed
21
0
Address Bit always decoded as “0”
20
0
Address Bit always decoded as “0”
19
1
J3A-4
Installed
18
1
J3A-5
Installed
17
0
J3A-6
Removed
16
0
J3B-1
Removed
15
1
J3B-2
Installed
14
0
J3B-3
Removed
13
0
J3B-4
Removed
Table 9
Example #3:
I/O Address 0x340 (BasicCAN mode)
0x340 = XXXX.XXXX.XXXX.X
011.01
CJ.JJJJ (binary)
Address
Bit
Bit
Value
J3A or J3B
Position
Installed
or Removed
23 -> 11
X
---
---
10
0
J3A-6
Removed
9
1
J3B-1
Installed
8
1
J3B-2
Installed
7
0
J3B-3
Removed
6
1
J3B-4
Installed
Table 10
Example #4:
I/O Address 0x600 (PeliCAN mode)
0x600 = XXXX.XXXX.XXXX.X
110.
CJJJ.JJJJ (binary)
Address
Bit
Bit
Value
J3A or J3B
Position
Installed
or Removed
23 -> 11
X
---
---
10
1
J3A-6
Installed
9
1
J3B-1
Installed
8
0
J3B-2
Removed
Table 11