beautypg.com

Bryant SERIES E 348 User Manual

Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

S E P / 1 0 / 2 0 0 8 / W E D 1 1 : 3 5

UTC TECH PUB

F A X N o , 3 1 7 2 4 0 5 6 6 2

valve are independent of the 24-volt circuit.

The ehippitig bolt should be removed from the

belt drive blower in accordance with label in­

structions on the blower.

Remove the burner shipping wire after the

furnace has been set in place. It is recom­
mended that flexible fireproof connections be

made from the unit to ductwork. Insulate all

ducts in attics and other cold areas .

CLEANING THE FURNACE

Burner shipping wire should have been re­

moved when furnace was first installed.

1. Shut off all electric and gas supply to the

furnace.

2.

Remove burner access panel (2 screws).

There is a panel on each side; either or both
may be used ,

3. The burner with pilot is located on either

the left or right end of the manifold.

After removing either or both..side access
panels* the burners may be removed in any
order with the burner with pilot being re­

moved first or last.

a. Burners that dp not have the pilot at^

tached;

' ' .

,w,

a - 1 . Lift upward out of back holding

slot-

a ^2. Piish burner to rear to disengage

/■ X\7f ^

' ' ";a-3'.''Withdm

through access

...... ........... '^'opening.

b . Burners that have, the pilot attached:

_7A.A7b.-T < Цíacdhh.¿cf:

. ■ ; by removing wire nuts, Tbis ap-

' A

fplies only fo Biyaht pilot. -.

—; "'-bT:2'i DiscohneC,t“^ilot■^gas■-^:Supply--m^

7' /y'aT,the .pilot valve .........AA5_'

—■ Biscohhkit-pilotvbiee

■ 'Biyant valve.

. ■ ...... On ip0%5 ilw-obf Apote

- disconnect thermocouple at auto­

matic shut-off valve.

b“3. Straighten all tubing disconnected

in (2) above so that it sticks

strai^t out towards the manifold
end of furnace,

b - 4 . Lift burner upwards out of hold­

ing slot* disengage from mani­

fold spud, and then rotate the
burner with attached pilot and tub“

ing So that the pilot is on the top
side.

b “ 5 . Remove entire assembly through

the access opening.

4. Disconnect vent pipe at draft hood.

5. Remove draft hood assembly.

6. Remove flue baffles from heat exchanger.

7. Use a flexible handled steel cleaning brush

to

loosen

scale

and

soot.

Remove

these

scrapings from bottom of combustion cbam-

ber.

8. ,Re-assemble furnace.

CARE AND MAINTENANCE

Care of Blowers:

Motors on the belt drive

blowers

are

provided

with

oil

wells,

and

should be oiled at least twice a year with a

good grade of SAE 30 oil, The motors on the
direct drive blowers are sealed units and do

not require the addition of oil.

Blower. beaH

semiApeirmhnentiylufei^^ :

cated'. ;;A^^

is normally good for

3 to .S .years-.--'-TOien necessary to add lubri­
cant, use ''Culf Plastic E".

Filters

should he examined f re -

■“qU!^ntly“^pr^,elpgging-^due to dirt-.---The dispo;^ —

able filters' ¡should'be replaced when they be-
come ;dji:ty;,i;.pem type filters may be

-eleaned-using"-oiea'r-'Water-;-eoat-"the^-^^^

Water 3 olublf;; 6 il afte r cleaning.

'

Cleaning"^: T^e heat

should be ex­

amined periodically to see if. th^

3;e has been

an laccumuiatldn of rust, soot* etc . Clean as

required.

- 7 -

348