valve are independent of the 24-volt circuit.
The ehippitig bolt should be removed from the
belt drive blower in accordance with label in
structions on the blower.
Remove the burner shipping wire after the
furnace has been set in place. It is recom
mended that flexible fireproof connections be
made from the unit to ductwork. Insulate all
ducts in attics and other cold areas .
CLEANING THE FURNACE
Burner shipping wire should have been re
moved when furnace was first installed.
1. Shut off all electric and gas supply to the
furnace.
2.
Remove burner access panel (2 screws).
There is a panel on each side; either or both
may be used ,
3. The burner with pilot is located on either
the left or right end of the manifold.
After removing either or both..side access
panels* the burners may be removed in any
order with the burner with pilot being re
moved first or last.
a. Burners that dp not have the pilot at^
tached;
' ' .
,w,
a - 1 . Lift upward out of back holding
slot-
a ^2. Piish burner to rear to disengage
/■ X\7f ^
■
' ' ";a-3'.''Withdm
through access
...... ........... '^'opening.
b . Burners that have, the pilot attached:
_7A.A7b.-T < Цíacdhh.¿cf:
. ■ ; by removing wire nuts, Tbis ap-
' A
fplies only fo Biyaht pilot. -.
—; "'-bT:2'i DiscohneC,t“^ilot■^gas■-^:Supply--m^
7' /y'aT,the .pilot valve .........AA5_'
—■ Biscohhkit-pilotvbiee
■ 'Biyant valve.
. ■ ...... On ip0%5 ilw-obf Apote
- disconnect thermocouple at auto
matic shut-off valve.
b“3. Straighten all tubing disconnected
in (2) above so that it sticks
strai^t out towards the manifold
end of furnace,
b - 4 . Lift burner upwards out of hold
ing slot* disengage from mani
fold spud, and then rotate the
burner with attached pilot and tub“
ing So that the pilot is on the top
side.
b “ 5 . Remove entire assembly through
the access opening.
4. Disconnect vent pipe at draft hood.
5. Remove draft hood assembly.
6. Remove flue baffles from heat exchanger.
7. Use a flexible handled steel cleaning brush
to
loosen
scale
and
soot.
Remove
these
scrapings from bottom of combustion cbam-
ber.
8. ,Re-assemble furnace.
CARE AND MAINTENANCE
Care of Blowers:
Motors on the belt drive
blowers
are
provided
with
oil
wells,
and
should be oiled at least twice a year with a
good grade of SAE 30 oil, The motors on the
direct drive blowers are sealed units and do
not require the addition of oil.
Blower. beaH
semiApeirmhnentiylufei^^ :
cated'. ;;A^^
is normally good for
3 to .S .years-.--'-TOien necessary to add lubri
cant, use ''Culf Plastic E".
Filters
should he examined f re -
■“qU!^ntly“^pr^,elpgging-^due to dirt-.---The dispo;^ —
able filters' ¡should'be replaced when they be-
come ;dji:ty;,i;.pem type filters may be
-eleaned-using"-oiea'r-'Water-;-eoat-"the^-^^^
Water 3 olublf;; 6 il afte r cleaning.
'
Cleaning"^: T^e heat
should be ex
amined periodically to see if. th^
3;e has been
an laccumuiatldn of rust, soot* etc . Clean as
required.
- 7 -
348