NOTE: The strainer tube assembly is 53" long.

4. Drain oil, clean strainer tube and reassemble using

a hydraulic pipe sealant on the threads.

5.

Remove the breather plug from breather tube. See

figure 4. Pour 3-1/2 gallons of Dexron automatic
transmission fluid ONLY into breather tube.

FIGURE 6

BEFORE STARTING

During initial break-in period, oil level should be

watched closely. See ENGINE MAINTENANCE.

Use MS classification oil. Do not use oils marked

only MM or ML or unmarked.

Above 32° use SAE 30; below 32° use SAE lOW.
These recommendations must be followed for best
performance and long life. .

Change oil first two (2) hours of operation and

check oil level every five (5) operating hours or
each time equipment is used.

Change oil every twenty-five (25) operating hours
or sooner if equipment is operated in extremely
dusty or dirty conditions. See figure 7.

NOTE

Carburetors are preset at the factory.
DO NOT attempt to make adjustments
at this time. See carburetor
instructions outlined under CAR­
BURETOR ADJUSTMENT.

FIGURE 7

TO START ENGINE

1.

Place control lever (on engine) in run position.

See figure 8.

2.

Move choke lever to CHOKE position. See

figure 9.,

3.

Rewind starter-use quick full arm stroke. Keep

firm grip on handle and return rope slowly.

TO STOP ENGINE

1.

Move control lever to STOP position. See figure

8-

2.

Remove high tension wire from spark plug to

prevent accidental starting by children while
equipment is unattended.