ENGINE AIR CLEANER
Clean and re-oil the foam pre-cleaner every three
months or ever 25 hours of operation, whichever
occurs first. Service the foam pre-cleaner more fre
quently if you operate the generator in extremely dusty
or dirty conditions (Figure 12):
• Turn KNOB counterclockwise to loosen.
• Remove COVER, FOAM PRE-CLEANER and PAPER FIL
TER.
• Remove foam pre-cleaner from cover
• Wash foam pre-cleaner in liquid detergent and water.
• Wrap foam pre-cleaner in a cloth and squeeze dry.
• Saturate foam pre-cleaner in engine oil. Squeeze to
remove excess oil and to distribute oil.
• Install foam pre-cleaner into cover, followed by paper filter.
Tabs at edges of paper filter must lock into slots on cover.
Once
each
year
or
every
100
operating
hours
(whichever comes first), replace the paper filter. The
new replacement filter must be a flame retardent type.
Figure 12—Engine Air Cleaner
1"====*=*^ PAPER
FILTER
FOAM
PRE
CLEANER
COVER
ENGINE SPARK PLUG
Clean engine spark plug and set gap to 0.030 inch
(0.76mm) every 100 hours of operation (Figure 14).
■Clean by scraping or wire brushing and washing with
commercial solvent. DO NOT BLAST CLEAN SPARK
PLUG.
CAUTION: Sparking can occur if wire terminal does
not fit firmly over spark plug terminal end. If neces
sary, reform wire terminal to obtain a tight fit.
Figure 14 — Engine Spark Plug
hours of operation or once each year, whichever
occurs first.
Figure 15 — Fuel Filter
CLEAN AIR INTAKE SCREEN
Clean all foreign material from the air intake screen
(Figure 13) at lease once every 100 hours of operation.
Clean more often if necessary.
Inspect the area around the generator exhaust muffler
periodically and remove all grass, leaves, dirt, etc. from
this area.
Figure 13 — Cleaning Air Intake Screen
SPARK ARRESTOR MUFFLER
If the generator is not equipped with a spark arrestor
exhaust muffler and is to be used on any forest cov
ered, brush covered or grass covered unimproved
land, you may have to install a spark arrestor. The
spark arrestor must be maintained in effective working
order by the vehicle owner/operator.
For assistance in ordering, installing and maintaining
spark arrestor exhaust mufflers, contact your nearest
authorized service facility.
Exhaust
mufflers
supplied
by
Generac
are
spark
arrestor types. Generac exhaust mufflers for IM gener
ators do not have a spark arrestor screen, but are of
the more efficient “toriod” or “swirl" type. To remove
carbon and combustion deposits from such mufflers,
remove the PLUG from muffler and run engine for
about 15 minutes. Shut engine down, let the muffler
cool and install the plug.
—
11