Engine oil requirements engine specifications, Generator specifications, Engine specifications – Generac Power Systems 0595-0 User Manual
Page 11: Specifications
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

SPECIFICATIONS
ENGINE OIL REQUIREMENTS
ENGINE SPECIFICATIONS
Use a high quality detergent oil classified “For Service Type of Engine.............................................. Twin Cylinder
SF” and with an oil viscosity rating of SAE 10W-30 oii.
Cooling Method............................. Air-cooled
Do not pour in any additives to the recommended oil.
Rated Horsepower.........................16 at 3600 rpm
'2, ■! -5 V-2-
2®®
Displacement................................. 479.4cc
MAINTENANCE section for oil level check and filling compression Ratio........................................... 8.6 tol
proce ures.
Cylinder Block................................Aluminum with cast
.....................................................iron sleeve
Type of Governor.......................... Mechanical, fixed
..................................................... speed
Engine Governed Speed............... See chart below
Air Cleaner.................................... Paper element with
..................................................... foam pre-cleaner
Starter........................................... 12 volts DC electric
Ignition System............................. Solid state with
..................................................... flywheel magneto
Recommended Spark Plugs
Champion:................................. RC12YC
Spark Plug Gap.............................0.030 inch (0.76mm)
GENERATOR SPECIFICATIONS
SERIES
IM-52G
IM-66G
IM-72G
Rotor RPM
3600
3600
3600
Rotor Poles
2
2
2
Engine RPM
2300
2700
2900
Wattage*
5200
6600
7200
Voltage*
240
240
240
Current*
21.7ACampsi
27.5 ampst
30 AC ampsV
Phase
1
1
1
Frequency
60 Hertz
60 Hertz
60 Hertz
Weight
185 pounds
194 pounds
200 pounds
Length
■ 25 inches
25 inches
25 inches
Width
18.5 inches
18.5 inches
18.5 inches
* All units are reconnectable to 120 volts, single voltage output.
t
Rated maximum continuous current at 120 volts is 43.3 amps,
t Rated maximum continuous current at 120 volts is 55 amps.
V Rated maximum continuous current 120 volts is 60 amps.
—
9
—