7500EXL Extended Life Generator
Id=lw^l=l=F±T-y
Parta DU rrodncti
STORAGE
The generator should be started at least once every seven
da)ra and a lowed to run at least 30 minutss. If this cannot
be done and you must store the unit for more than
30 days, use the following guidelines to prepare it for
storage.
Generator Storage__________________
• C ean the generator as outlined in “To Clean the
Generator.”
• Check that cooling air slots and openings on generator
are open and unobstructed.
Engine Storage
WARNING
Storage covers can be flamntnble.
; DO NOT; place a stora^ cover; over a; hoi gororaton ;;
: LoC equipment cool for a sufficient time before placing the
: cover on the equipment:::::::::::::::::::::::::::::::::
See engine owner’s manua for instructions.
Other Storage Tips
To prevent gum fram forming in fue system or on
essential carburetor parts, add fuel stabilizer into fuel
Шпк and fil with fresh fue, Run the unit for several
minutes to circu ate the additive through the carburetor.
The unit and fue can then be stored for up to
24 months. Fue s^bilizer can be purchased loca ly,
DO NOT store fuel from one season to another unless
it has been treated as described above.
Replace fuel conuiner if it surts t» rust. Rust and/or dirt
in fuel can cause problems if it‘s used with this unit.
Store unit in a clean and dry area.
TROUBLESHOOTING
РтоЫепп
Cause
Correction
No ДС output is available,
but engine is running.............
: One :of thé:CÌrCUÌt:brèaterS:ÌS: Орёп;....1. Reset dixutt breaker.
2, : : : Faultin generator"............................... 2, Contact Generile service facility.
3. : : : РООГ: СОППесИОП :ЬГ: defective cor d set.: : :
;3.;;;;Check; and; repair.....................
4, Connected; device ;is; bad.
4, Connect another; device; diat;is ; in
.......good condit on. ...........................
Engine runs good at: no^:
I load but
■ down”
iwhién; ioadis connected.
I , Short circu Ч in a co'^ected toad,
2. Ge-erator’s overoaded.
3, Shorted generator c rcuit.
; Diisconh:ect;s;horted; electrical ;|cKid,
iSeel-'Dlbn-tOverload Generator".;
Contact Ge~erac service fecility.
Engine will not starts or
starts and runs njugh.
1; Fuel iValve; is; in the; “Off'; position.;
2.;;; Failed; battery.
;Turn; ;fuel та1Уе to ‘'On" position.
Rep ace battery.
Engine shuts down during
operation, ...............................
Out ;of gasoline,;
Fill fuel;tank.
Engine lacks power.
Load ;ls;too; high,;
See "Don’t O^rload Generator".