PRIMEPACT 50 Recreational Vehicle Generator
Figure 2.15 - Typical Propane Gas Fuel System
• 2.5.2
SOME
IMPORTANT
CONSIDERATIONS
When installing an LP gas system, consider seriously
the following items:
• All fittings, lines, hoses and clamps must be tight
and free of leaks. Apply a pipe sealant to threads
when
assembling
threaded
connections.
This
reduces the possibility of leakage.
• Test the entire fuel system for leaks using approved
test methods.
• Optimum gas pressure at the inlet to the gaseous
fuel solenoid valve and secondary regulator is 11
inches water column.
• The Installer’s fuel supply connection point is at
the gaseous fuel solenoid valve. This is a 3/4-inch
(female) connection. Provide a suitable 3/4-inch
NPT (male) connector to attach to the fuel supply
line.
“ Use a length of approved flexible fuel hose between
the gaseous fuel solenoid valve and rigid gas pip
ing. The flexible line should be at least 6 inches
longer than necessary.
• 2.5.3 VAPOR WITHDRAWAL
LP gas is stored in pressure tanks as a liquid. The
gas systems used with these generators were
designed only for vapor withdrawal type systems.
Vapor withdrawal systems use the gas vapors that
form above the liquid fuel in the tank. Do NOT
attempt to use the generator with any liquid with
drawal type system.
♦ 2.5.4 PRIMARY REGULATOR___________________
Gas pressure delivered to the solenoid valve must be
properly regulated by means of a primary gas regula
tor. Mount the primary regulator at the gas tank out
let or in the supply line from the gas tank. The fol
lowing rules apply:
♦ For best results, the primary regulator supplies
gaseous fuel to the secondary regulator at 11 inch
es water column. Do NOT exceed 14 inches water
column.
•• The installer must be sure the primary regulator is
rated at sufficient gas flow to operate the generator
plus all other gas appliances in the circuit.
NOTE:
Recommended MINIMUM gas flow rate for all air
cooled PRIMEPACT series generators is 67 cubic
feet per hour.
If an existing primary gas regulator does not have
a sufficient flow capacity for the generator and
other gas appliances in the circuit, (a) install a pri
mary regulator with adequate flow rate, or (b)
install a separate regulator only and rated at least
67 cubic feet per hour. The inlet side of any pri
mary regulator that supplies the generator must
connect directly to a gas pressure tank. Do NOT
tee the generator line into a gas circuit feeding
other areas.
♦ 2.5.5
GASEOUS CARBURETION
LP gas vapors should be supplied to the secondary
regulator inlet at about 11 inches water column (pos
itive pressure). The engine pistons draw air in during
the intake stroke (Figure 2.16). This air passes
through a carburetor venturi, which creates a low
pressure that is proportional to the quantity of air
being pumped. The low pressure from the carburetor
venturi acts on the regulator diaphragm to pull the
diaphragm toward the source of low pressure. A lever
attached to the diaphragm opens a valve to permit
gas glow through the carburetor.
Figure 2.16
-
LP Gas Carburetion Diagram
AIR
FLOW
GASAI
POSITIVE
PRESSURE
LOW PRESSURE
AREA
GAS AT
ZERO PRESSURE