Fig. 29—typical fan coil with 2-speed heat pump, Fig. 30—fk4c fan coil with 2-speed heat pump – Carrier WEATHERMAKER ZONEKIT2ZCAR User Manual

Page 16

background image

Fig. 29—Typical Fan Coil With 2-Speed Heat Pump

A97310

RH

G

W2

W1

Y1

Y2

O

B

RC

2-SPEED

HEAT PUMP

TYPICAL

FAN COIL

C

G

W2

Y/Y2

R

C

W3

L

E

Y1

R

W2

O

W3

Y1

Y2

O

TWO-ZONE SYSTEM

See notes 1, 2, 3, 9, and 11

*

*

*

*

*

Fig. 30—FK4C Fan Coil With 2-Speed Heat Pump

A97311

FK4C

FAN COIL

R

R

G

W1

C

DH

W2

Y1

Y/Y2

O

C

W2

Y1

Y2

RH

G

W2

W1

Y1

Y2

O

B

RC

2-SPEED

HEAT PUMP

TWO-ZONE SYSTEM

J1 JUMPER

J2 JUMPER

O

W3

See notes 1, 2, 9, and 11

WIRING DIAGRAM NOTES

1. Refer to fan coil Installation Instructions for proper wiring.

2. Refer to outdoor unit Installation Instructions for latent kit requirements.

3. Terminals marked with * may not be present on equipment.

4. Interface control transformer must be in phase with furnace transformer to get high-speed fan during heat pump operation.

5. Heat pump MUST have a high-pressure switch for dual-fuel applications.

6. Two-Zone Control does not know that dual fuel is applied. Do not use thermostat AUTO CHANGEOVER mode with dual-fuel

applications, keep both thermostats in same mode (heating or cooling).

7. Configure Two-Zone Control board (jumpers) for:

(J1) T-stat = Fnc
(J3) Equipmt = HP
(J4) Fnc Ht = w/fan
(J5) LAT = Set LAT jumper high enough to allow furnace to come on during defrost and second-stage operation.
(J7) DTO = On

8. Furnace must control its own second-stage heat operation, via the furnace control algorithm.

9. Refer to outdoor equipment Installation Instructions for proper set up.

10. Select Furnace Interface option, Balance Point, and Defrost Time on 2-speed heat pump control board.

11. DO NOT select "ZONE" position on 2-speed heat pump control board. In heating mode, heat pump outdoor temperature sensor will control

the compressor low- and high-speed change.

Copyright 1997 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231

zkit8si

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

1

4

4

Tab

3a 5a 2a 5a

PC 101

Catalog No. 809-500

Printed in U.S.A.

Form ZONEKIT-8SI

Pg 16

6-97

Replaces: ZONEKIT-2SI