16
TO TIME THE SHUTTLE
Turn hand wheel until eccentric stud is aligned with
screwdriver hole D2, Fig. 37.
1/3
K-DISTANCE
r'
Fig, 37. Location of Eccentric Stud for Timing Shuttle
Fig. 38. Correct Timing of Shuttle Carrier
To time the shuttle, turn eccentric stud at hole D2
until the leading edge of the shuttle carrier moves at
each
oscillation
to
a
position
approximately
one-third
the
distance
across
the
needle
slot
below
the
face
plate as shown in Fig. 38.
NOTE: Shuttle is removed in Fig. 38 to illustrate
correct timing of leading edge of shuttle carrier.