NOTE: Where the exhaust passes through a
wall, ceiling, or roof made of combustible
materials, the opening must be 2-inches larger
(all the way around) than the duct. The duct
must be centered within this opening.
IMPORTANT: DO NOT use screens, louvers, or
caps on the outside opening of exhaust duct
work.
ELECTBIICAL INFORMATION
1. Electrical Requirements
It is your responsibility to have ail electrical
connections made by a properly licensed
and competent electrician to assure that the
electrical installation is adequate and
conforms with local and state regulations or
codes. In the absence of such codes, all
electrical connections, material and work
manship must conform to the applicable
requirements of the National Electric Code
ANSI/NFPA No. 70 (Latest Edition), or in
Canada, the Canadian Electrical Codes,
Parts 1 & 2 CSA C22.1 - 1 9 9 0 or Latest
Edition.
Each dryer should be connected to an inde
pendently protected branch circuit. The dryer
must be connected with copper wire only. DO
NOT use aluminum wire which could cause a
fire hazard. The copper conductor wire/cable
must be of proper ampacity and insulation in
accordance with electric codes for making ALL
service connections.
NOTE: Wiring diagrams are affixed to the inside
at the top front control door and to the rear
upper back guard/panel.
ELECTRICAL SERVICE
SPECIFICATIONS
Reversing, 3-Phase Motor
NOTES:
A. Fuse ratings are dual element-time delay-
current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic
(industrial) type ONLY. For others, calculate/
verify correct breaker size according to
appliance amp draw rating and type of
breaker used.
C. Circuit breakers for 3-phase dryers must be
3-pole type.
Service Voltage
230
Phase
30
Wire Service
3
Approx. AMP Draw (60 Hz)
13
Minimum Wire Service
12
Fusing (Dual Element Time Delay)
20
Circuit Breaker
25
IMPORTANT: The dryer must be connected to
the electrical supply shown on the data label
that is affixed to the back of the dryer, at the
upper right hand corner.
WARNING: 208VAC and 230/240 VOLTS ARE
NOT THE SAME. Any damage done to dryer
components due to improper voltage connec
tions will automatically VOIDTHE WARRANTY.
IMPORTANT: Failure to comply with these
codes ordinances, and/or the requirement
stipulated in this manual can result in personal
injury or component failure.
NOTE: Component failure due to improper
installation voids the warranty.
It is recommended that a separate circuit
serving each tumbler be provided. The dryer
must be connected with copper wire only. Do
not use aluminum wire which could cause a fire
hazard.
NOTE: The use of aluminum wire voids the
warranty.
ELECTRICAL CONNECTIONS
NOTE: A wiring diagram is included with each
dryer and is affixed to the rear, upper right
guard/panel of the dryer.
The only electrical input connections to the
dryer are the 3-phase (3o) power leads (LI, L2,
and L3), GROUND, and in the case of 4 wire
service, the neutral. Providing local codes
permit, power connections to the dryer can be
made by the use of a flexible underwriters
laboratory listed cord/pigtail (wire size must
conform to rating of the dryer), or the dryer can
be hard wired directly to the service breaker. In
ALL cases, a strain relief must be used where
the wire(s) enter the dryer electrical service
(relay) box.
13