Instructions for Installation (cont'd)

Wiring

A CAUTION

Never use this water heater unless it is completely

full of water. To prevent damage to the tank and

heating element, the tank must be filled with

water. Water must flow from the hot water faucet
before turning on power.

You must provide all wiring of the proper size outside of the
water heater. You must obey local codes and electric company

requirements when you install this wiring.

If you are not familiar with electric codes and practices, or if

you have any doubt, even the slightest doubt, in your ability to

connect the wiring to this water heater, obtain the service of a
competent electrician. Call Maytag Customer Service at

1-800-788-8899 for an authorized servicer.

A WARNING

WATER HEATERS EQUIPPED FOR ONE VOLTAGE
ONLY: This water heater is equipped for one type
voltage only. Check the rating plate near the bot­
tom access panel for the correct voltage. DO NOT

use this water heater with any voltage other than

the one shown on the model rating plate. Failure to

use the correct voltage can cause problems which

can result in DEATH, SERIOUS BODILY INJURY, OR

PROPERTY DAMAGE. If you have any questions or

doubts consult your electric company.

A CAUTION

If wiring from your fuse box or circuit breaker box
was aluminum for your old water heater, replace it

with copper wire. If you wish to reuse the existing

aluminum wire, have the connection at the water
heater

made

by

a

competent

electrician.

Call

Maytag Customer Service at 1-800-788-8899 for an
authorized servicer.

1. Provide a way to easily shut off the electric power when

working on the water heater. This could be with a circuit

breaker or fuse block in the entrance box or a separate dis­
connect switch.

2. Install and connect a circuit directly from the main fuse or

circuit breaker box. This circuit must be the right size and
have its own fuse or circuit breaker. Refer to the chart in
the “Product Specifications” section for the correct size

wire and fuse or circuit breaker.

3. If metal conduit is used for the grounding conductor:

A. The grounding electrode conductor shall be of copper,

aluminum, or copperclad aluminum. The material shall
be of one continuous length without a splice or joint.

B. Rigid metal conduit, intermediate metal conduit, or

electrical metalhc tubing may be used for the grounding
means if conduit or tubing is terminated in fittings

approved for grounding.

C. Flexible metal conduit or 3 metallic tubing shall be per­

mitted for grounding if all the following conditions are
met:
1. The length in any ground return path does not exceed

6 feet.

2. The circuit conductors contained therein are protected

by overcurrent devices rated at 20 amperes or less.

3. The conduit or tubing is terminated in fittings

approved for grounding.

For complete grounding details and all allowable exceptions,

refer to the latest edition of the National Electrical Code.

4. A standard ‘A" conduit opening has been made in the water

heater junction box for the conduit connection.

5. Wiring Diagrams (See “Wiring Diagrams” Section) have

been supplied showing the two most common types of con­

nections between the water heater and the power supply.

You can easily see which type connection you have by
removing the junction box cover on top of the water heater.
A.

Two Wire Connection Diagrams; is the most common

requiring you to simply connect red to red, black to black,

and the ground wire to the green ground screw in the junc­

tion box of the water heater.

B. Three Wire Connection Diagram: is used when you are

connecting the water heater to power a supply that has a

“Time Clock” or “Off Peak” Meter. To make these connec­

tions refer to block 1 or 2 in this wiring diagram for the type

of system you have.

NOTE: If you have purchased a three wire connection
water heater but you are not on a “Time CloclY or “Off

Peak” meter and have a standard two wire connection

power supply, simply foUow the connection diagram in
block 3 of the Three Wire Connection Diagram.

6. Use wire nuts and connect the power supply wiring to the

wires inside the water heater's junction box.

7. The water heater must be electrically “grounded” by the

installer. A green ground screw has been provided on the

water heater's junction box. Connect ground wire to this
location.

8. Replace the wiring junction cover using the screw provided.