1. Before beginning the conversion turn “OFF” electric

power supply to the water heater.

4. Lower Element: Lift out the tab as shown to unclip the

terminal cover from the thermostat. The terminal cover
can now be removed from the thermostat.

Lift out tab to undip

terminal

cover

from

thermostat.

A WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing

any access panels or servicing the water heater,
make sure the electrical supply to the water heater
is turned "OFF". FAILURE TO DO THIS COULD
RESULT IN DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.

2. The convertible element is located behind the lower access

panel of the water heater. Remove the two screws securing
the access panel, and remove panel.

5. Remove the screws from terminal 2 of the element, and

move the looped end of the wire aside.

3. Open the flap of insulation to expose the opening.

6. The buss bar is labeled 5500 W. Place the buss bar over ter­

minals 2 and 3 with the 5500 W visible. Install the extra
screw provided into terminal 3.