7.13 Details of Command and Option

Title

Command

FLCE /Y

This command sets up the device, baud rate, and communication mode used for communication.

If this command is omitted, the default value {IrDA, , } is used.

Any of the parameters can be omitted. If this is done, the default values for each parameter will be used.

Always insert this command directly after the word “FLCE”. Placing it in another place will result in a parameter

error.

C Language Interface

Calling Sequence

FLCE /Y={ [], [], [] }

(Comma must be written and no space allowed. Parameters in [ ] can be omitted.)

Parameters

Device

Select either "IrDA" or "COM1".

Baud rate

If "IrDA" is selected – the baud rate setting can not be allowed.

If "COM1" is selected - The following baud rates can be selected for RS-232C communication.

9600, 19200, 38400, 57600, 115200

Combinations other than those described above are not permitted and will cause a parameter
error.

Mode

"H" - PA-2400W-to-PA-2400W command specification mode (Session-wait timeout is

1 minute.)
This option is used by one side which specifies the operation command when performing
communication between two PA-2400Ws.
(The FLCE on the communication partner should operate in the idle start mode.)

"I" - Normal mode (Session-wait timeout is infinite.)

Only "H" or "I" can be specified.

If mode specification is omitted, the normal mode with the session-wait timeout set to 1

minute is automatically specified.

Table 7.7

Session Wait Timeout

Startup

Communication Partner

1 minute

Infinite

Idle (including script)

PC (I/O Box)/PA-2400W
PC (I/O Box)

No mode
specification

Mode
Specification, “I”

Designation of
Operation command

PA-2400W

Mode
specification, “H”

-

Startup Examples

FLCE /Y={COM1, 115200, } /S "\casio\*.dat" "d:\casiodat\"

Communication is performed using the RS-232C port at a baud rate of 115.2 Kbps. (Session-wait timeout
is 1 minute.)

FLCE /Y={, , I} /S "\casio\*.dat" "d:\casiodat\"

Communication is performed through command specification with the device name and the baud rate
are default-set. (Session-wait timeout is infinite.)

FLCE /Y={, , H} /S "\casio\*.dat" "d:\casiodat\"

Communication is performed between two PA-2400Ws through command specification with the device
name and the baud rate are default-set. (Session-wait timeout is 1 minute.)

FLCE /Y={, , I}

Communication is performed in the idle mode with the device name and the baud rate are default-set.
(Session-wait timeout is 1 minute.)

FLCE /Y={, , } /S "\casio\*.dat" "d:\casiodat\"

Communication is performed under the same conditions (with default values) of which "/Y" is omitted.