beautypg.com

Casio PA-2400W User Manual

Page 55

background image

55

Table 7.6 List of termination codes

Error Code

Category

code

Detail

code

Meaning

Possible Cause

Remedy

00h

00h

Normally terminated

Normal.

-

DCh to

F5h

00h

Normally terminated

Formatting of drive a:between 'A'
and 'Z' is specified from the
partner station. (For drive letter
definitions, refer to Chapter
7.7 “Method of Describing
Pathname”.)

Refer to Chapter 7.5
“Restrictions”.

F6h

00h

Normally terminated

Power-off is specified from the
partner station.

Turn off the power.

F7h

00h

Normally terminated.

Resetting the power is specified

from the partner station.

Refer to Chapter 7.5
“Restrictions”.

F8h

00h

Terminated due to interruption.

Communication is terminated
because the break key is pressed
on the PA-2400W (local station)
or partner station.

Resume communication as
required.

01h

00h

Protocol error

Data anomaly (data error
occurred on the communication
line).

Check the communication
line connection.

02h

80h

File not found

Non-existent file is specified.

Check the specified file or
directory.

02h

81h

Current directory delete error

An attempt has been made to
delete the current directory.

Check the objective
directory of deletion.

02h

82h

File write error

Write to the file is not possible.

Check if the file is ready to
be written.

02h

83h

File read error

Read from the file is not possible.

Check if the file is ready to
be read from.

02h

84h

Read only access error

An attempt has been made to
overwrite or delete the read-only
file.

Specify another file name or
cancel the read-only
attribute.

0Fh

01h

Argument parameter error

Incorrect argument description

Check the argument
parameter.

0Fh

02h

Argument too long

Argument portion of the
command line is too long

Reduce the length of the
argument including FLCE to
255 characters or less.

A0h

10h

Communication port open error

One of the other programs is
using COM1 or IrDA,or FLCE is
already initiated.

Terminate the program that
is using COM1 or IrDA.

Either the cable was unplugged
during communication or the
IrDA connection is broken
(where the PA-2400W is
dismounted from I/O Box).

Check the cable connection
and mounting condition of
the PA-2400W on I/O Box.

A0h

20h

Line break error or IrDA
duplicate open error

IrDA port is already open.

Terminate the other
program that is using IrDA.

A0h

30h

Session-wait timeout error

Session was not established
within 1 minute of startup.

Check the cable connection
or check if the IrDA is ready
for communication.