Casio PA-2400W User Manual
Page 55

55
Table 7.6 List of termination codes
Error Code
Category
code
Detail
code
Meaning
Possible Cause
Remedy
00h
00h
Normally terminated
Normal.
-
DCh to
F5h
00h
Normally terminated
Formatting of drive a:between 'A'
and 'Z' is specified from the
partner station. (For drive letter
definitions, refer to Chapter
7.7 “Method of Describing
Pathname”.)
Refer to Chapter 7.5
“Restrictions”.
F6h
00h
Normally terminated
Power-off is specified from the
partner station.
Turn off the power.
F7h
00h
Normally terminated.
Resetting the power is specified
from the partner station.
Refer to Chapter 7.5
“Restrictions”.
F8h
00h
Terminated due to interruption.
Communication is terminated
because the break key is pressed
on the PA-2400W (local station)
or partner station.
Resume communication as
required.
01h
00h
Protocol error
Data anomaly (data error
occurred on the communication
line).
Check the communication
line connection.
02h
80h
File not found
Non-existent file is specified.
Check the specified file or
directory.
02h
81h
Current directory delete error
An attempt has been made to
delete the current directory.
Check the objective
directory of deletion.
02h
82h
File write error
Write to the file is not possible.
Check if the file is ready to
be written.
02h
83h
File read error
Read from the file is not possible.
Check if the file is ready to
be read from.
02h
84h
Read only access error
An attempt has been made to
overwrite or delete the read-only
file.
Specify another file name or
cancel the read-only
attribute.
0Fh
01h
Argument parameter error
Incorrect argument description
Check the argument
parameter.
0Fh
02h
Argument too long
Argument portion of the
command line is too long
Reduce the length of the
argument including FLCE to
255 characters or less.
A0h
10h
Communication port open error
One of the other programs is
using COM1 or IrDA,or FLCE is
already initiated.
Terminate the program that
is using COM1 or IrDA.
Either the cable was unplugged
during communication or the
IrDA connection is broken
(where the PA-2400W is
dismounted from I/O Box).
Check the cable connection
and mounting condition of
the PA-2400W on I/O Box.
A0h
20h
Line break error or IrDA
duplicate open error
IrDA port is already open.
Terminate the other
program that is using IrDA.
A0h
30h
Session-wait timeout error
Session was not established
within 1 minute of startup.
Check the cable connection
or check if the IrDA is ready
for communication.