PARTS OF THE THERMOSTAT
Refer to fig. 1 for location of the following parts
of the thermostat (fig. 1 shows heating/cooling
thermostat model with cover removed).
1. Timer dial (rotates counterclockwise to re-
move/replace timer selectors or to set cur
rent time).
2. BLUE timer selectors are used to select the
setback times (the times when the thermo
stat will begin to maintain the lower tem
perature, indicated by the blue (LO) tem
perature lever).
3. RED timer selectors are used to select the
setup times (the times when the thermostat
will begin to maintain the higher tempera
ture, indicated by the red (HI) temperature
lever).
4. Time reference marker indicates current
time.
5. Fan selector switch (heating/cooling model
only). In AUTO position, fan cycles with
heating or cooling system. In ON position,
fan runs continuously, regardless of system
operation.
6.
System selector switch (heating/cooling
model only). In COOL position, cooling
system operates. In OFF position, neither
heating nor cooling system operates (but
fan may still run if fan switch is in the ON
position), in HEAT position, heating system
operates.
7.
Red (HI) temperature lever indicates the
high temperature to be maintained.