background image

MAINTENANCE AND TROUBLESHOOTING

Inspect and properly tighten ali parts of the exercise

cycle regularly. Replace any worn parts immediately.

To clean the exercise cycle, use a damp cloth and a
small amount of mild soap—

never use alcohol,

abrasives, or chemicals to clean the exercise

cycle.

Important: To avoid damage to the console, keep

liquids away from the

console

and keep

the

con­

sole out of direct sunlight.

PULSE SENSOR TROUBLESHOOTING

For optimal performance of the pulse sensor, keep the
metal contacts clean. Clean the contacts with a soft

cloth —

never use alcohol, abrasives, or chemicals

to clean the metal contacts.

Avoid moving your hands or squeezing the metal con­
tacts too tightly while using the pulse sensor; doing so

may interfere with heart rate readings. For the most
accurate heart rate reading, hold the metal contacts

for about 15 seconds.

HOW TO ADJUST THE REED SWITCH

If the console does not display correct feedback, the

reed switch should be adjusted. To adjust the reed

switch, the pedals and the side shields must be

removed.

Using an adjustable wrench, turn the left pedal clock­

wise and turn the right pedal counterclockwise to

remove the pedals.

Next, remove the screws from the left and right side

shields. Note: There are two different sizes of screws
in the side shields. Make sure to note the location of
each screw. Then, carefully remove the side shields.

Next, locate

the Reed
Switch (21).
Turn the
Crank (13)
until the

Magnet (16)
is aligned with

the Reed
Switch.

Loosen, but

do not
remove, the
indicated

M5

X

12mm Screw (9). Slide the Reed Switch slightly

closer to or away from the Magnet, and then retighten
the Screw. Turn the Crank for a moment. Repeat until
the console displays correct feedback.

When the reed switch is correctly adjusted, reattach
the side shields and the pedals. To reattach the ped­
als, turn the left pedal counterclockwise and turn the
right pedal clockwise.

BATTERY REPLACEMENT

If the console display becomes dim, the batteries

should be replaced; most console problems are the
result of low batteries. To replace the batteries, see
assembly step 5 on page 6.

16