Troubleshooting
Trouble
Probable Cause
Remedy
Unit will not run.
* Humidity level is too high
• No power
• Raise humidistat setting
• Check 120 volt power source
Unit will not shut off-
• Float is not free
• Free float from obstruction
Unit will not dry out
completely
• Water is present in the
system
• High humidity or
tow
temperature resulting in
slow evaporation
• This is normal. A small
amount of water remains in
the cabinet,
• Allow unit to continue opera
tion.
Bottle continues to
empty.
• Air is entering water reser
voirs.
• Check “E-Z-Fi!l Side-Caps" to
ensure tightness.
• Check for leak in water bottle.
" Are gaskets for “E-2-Ftll Side-
Caps" in place (see repair
parts list).
Unit is not emptying.
• Dirty filter
• Reservoir cap plunger
missing post in bottom of
cabinet.
■ Change to a fresh new filler.
• Check orientation of bottle.
Reposition so that reservoir
cap plunger is depressed by
post in bottom of cabinet.
Unit runs and shuts
off before bottle is
empty
• Humidity level is loo high
• Unit is not setup on a level
surface (Float will not
sense water at the rear- of
the cabinet.
' Raise humidistat setting (if
possible)
• Position unit level (Some car
pet padding may allow unit to
set tower on the left side than
the right side due to the weight
of the water bottle on left side.
Install coasters under (eft cast
ers.)
CAUTION: Use only 42-14900 EPA Registered Bacteriostai available from
Sears Retail store.
Use of other water treatment products may damage the filter elements.
Under no circumstances should you use \water treatment products designed
for Roto bettor Ultrasonic humidifiers.