*hysiccd data
m
OUTDOOR AIR COOLING COIL
Face Area (sq ft)
Corrugated Fins/in ...Rows
EVAPORATOR COILS (zone)
No. ...Face Area (sq ft, ea)
Corrugated Fins/in .Rows
HEATING SECTION (48MA)
Rise Range
Input (1000 Btuh)
Total
Each Module
Bonnet Cap (1000 Btuh) Total
Full Rate
HEATING SECTION (SOME Electric)
Electric Heaters
No . .Elements (ea)
fiiMTNG SECWON (ici/ii*GTvcoii
Max Allowable Inlet Temp
Max Allowable Flow, Each Coil
Solution Mixture
Max Allowable Working Pressure
Total Internal Volume (gallons)
PRESSURE SWITCHES
Low-Pressure
Cutout
Cut-in
Cutout
Cut-in
High-Pressure
Indoor Airflow Switch (AFS 1
Factory Setting (cfm)
Adjustment Range (cfm)
INDOOR AIR FILTERS
Std No. ..Size (in )
High Efficiency (optional)
No. . Size (in )
Roll Media (optional)
OUTDOOR AIR FILTERS
No . Size (in )
UNIT 48MA/50ME
016
024
028
030
034
040
Zone Modules
8
8
10
10
12
12
Nominal Cooling Capacity (tons)
15
20
25
28
30
37
OPERATING WEIGHT
Tib)
Base Unit 48MA
3385
3805
4075
4080
4800
5700
Base Unit SOME (with heat)
2985
3405
3665
3670
4400
5250
Roof Curb
506
506
506
506
630
630
REFRIG CHARGE (lb, R-22)
28
32
43
43
57
66 1
COMPRESSOR
Reciprocating Hermetic. 1725 Rpm
No. 1 Type
06DE537
06DE824
06DE537
06DE537
06DE537
06EE250
Cylinders. Unloaders
6 2
6.2
6 ..2
6.2
6.2
4.1
No. 2 Type
—
06DA824
06DA824
06DA537
06DA537
06EA250
Cylinders (has no unloaders)
—
6
6
6
6
4
System Oil Charge (pts)
.... " .
22
22
22
21
31
Unloader Settings (psig)
Compressor No 1 Only
Left Bank
71 0 ± 1 5
57 5 ±25
—
Right Bank
760 ± 1 5
62 5 ±25
75 5 ± 1 5
58 0 ± 2 5
Capacity Steps (%)
100,67,33
100,83,67
50,33,17
100,80,60
40,20
100,80,60
40,20
100,83,67
50,33,17
100,75,
50,25
OUTDOOR AIR FANS
Propeller, Direct Drive
Motor Hp .Rpm...Frame (NEMA)
No 1
1 1075 56(1-phase)
No. 2
1 1140 56 (3-phase)
No 3
—
—
—
-
1.1140 56 (3-phase)
Nominal Cfm
16,500
15,000
15,000
15,000
24,000
23,000
INDOOR AIR FANS
Centrifugal; Belt Drive
No. ...Size (in.)
2 1 5 x 1 5
2 1 5 x 1 5
2 1 5 x 1 5
2 . 1 5 x 1 5
3 . . 1 5 x 9
3 . . 1 5 X 9
Cfm (Nom)
6000
8000
10,000
10,000
12,000
12,000
Motor Hp .Rpm
5 1725
7-1/2 1725
10 1725
10 1725
15 1725
20 1725
15
1725
20 1725
Fan Pulley
Outside Diameter (in )
10 6
10 6
80
80
8.0
80
Bore (in.)
1-3/16
1-3/16
1-3/16
1-3/16
1-11/16
1-11/16
Fan Belt No ..Size w/Std Mtr
1 3V630
1 3V630
2 3V560
2 3V560
2 3V630
2 3V630
w/Opt Mtr
—
—
—
3 3V670
3 3V670
Motor Pulley A
Factory Installed
OutsideDiam(in.) w/Std Mtr
5 3
60
50
50
50
50
w/Opt Mtr
—
—
—
—
6.0
6.0
Bore (in.)
1-1/8
1-3/8
1-3/8
1-3/8
1-5/8
1-5/8
Resulting Fan Rpm w/Std Mtr
880
995
1095
1095
1095
1095
w/Opt Mtr
—
—
—
—
1320
1320
Motor Pulley B
Shipped With Unit
Outside Diam (in.) w/Std Mtr
60
69
56
5 6
5 6
56
w/Opt Mtr
—
—
—
—
6 5
6 5
Resulting Fan Rpm w/Std Mtr
995
1145
1230
1230
1230
1230
w/Opt Mtr
—
—
—
—
1425
1425
6 8
13 2
8
.
.2
12
13 3
432
54
324
40 5
6 8
13 2
Thermostatic Expansion Valve, Hot Gas Bypass
6
8
1
6
8
13 2
13 2 i
1 0 2
13 2
8
.
.2
12
13 3
Solenoid Valve and Capillary Tube for each
I 1 0 . 2 1 2 I 1 0 . 2 1 2 I
I
13 3
j
13 3
I
Furnace Assembly in Each Zone Module
25 F to 55 F at 0 75 in wg ESP
1 2 . 2 0 1
12 3
1 0 2
13 3
1 2 . 2 0 1
15 3
432
540
540
648
54
54
54
54
324
405
405
486
40 5
40 5
40 5
40 5
8 2 or 3
2 61
■ or 3-Stage, Nichrome, Open-Wire Flesistance Elements in Each Zone Module
8 2 o r 3 J_ 10 2 or 3 I 10 2 or 3
[ 12 2 or 3
|
One Heating Coil in Each Zone Module
200 F
6 Gpm
20% Glycol
30 Psig
648
54
486
40 5
12 2 o r 3
2 61
3 15
3 15
3 76
3 76
29 + 5 Psig
39 ± 5 Psig
400 ± 5 Psig
300 ± 5 Psig
6000
4000-600
9000
6000-9000
12 20 x 25 x2
Same but with 36 5% efficiency (NBS Dust Spot Test)
65 ft of 2-in media
2 20 X 25 X 1
2 32
X
35
X
1