SAFETY CONSIDERATIONS

Installation and servicing of air conditioning

equipment can be hazardous due to system pres­
sure and electrical components. Only trained and
qualified service personnel should install, repair or
service air conditioning equipment.

Untrained personnel can perform basic mainte­

nance functions of cleaning coils and filters and
replacing filters. All other operations should be per­
formed by trained service personnel. When working
on air conditioning equipment, observe precautions
in the literature, tags and labels attached to the unit
and other safety precautions that may apply.

Follow all safety codes. Wear safety glasses and

work gloves. Use quenching cloth for unbrazing
operations. Have fire extinguisher available for all
brazing operations.

W.ARMNCi: llefore performing service or

maintenance operations on unit, turn off main

power switch to unit. Turn off accessoi\ healer

power switch if applicable, filectrical shock

could cause personal injury.

MODULAR SYSTEM INTRODUCTION

Field assemble the required 28 Series direct-

expansion (encased) coil and/or 40FS,40FQ,38HQ
accessory electric heater to 40FS fan section.
Combine fan section and coil for a split system fan
coil; fan section and accessory electric heater for
an electric furnace; fan section, coil and electric
heater for a heating and cooling unit. (See Table 2
for total height dimension of assembled units.)

Table 2 — Height Dimensions of Assembled Units

MODULAR UNIT ASSEMBLIES

TOTAL HEIGHT'i (ft-in.)

Cooling and Heating Unit

Airflow

Cooling Unit 1 —

Upflow

(or Horizontal)t

Downflow

Heating Unit

Coil

Fan Section

Elec Heater

28H0036020

28VQ036020

-

-

-

40FS160

40FS,FO916

38HQ9000**

3-11’^X6

4- OVe

28HQ042030
28HQ048020

28VQ042030
28VQ048030

28TQ042

-

■ -

40FS160

40FS.F0916
38HQ9000**

4-

SM,

4-

7Va

28H0042020

28HQ048020

28VQ042020
28VQ048020

-

280X036
280X042

-

40FS200

40FS91 6,920

40F0920

38H09001*

4- 3=46
5- OVsft

4- 3=46
5- 0%tt

28HQ060020

28VQ060020

28TQ060

-

-

40FS200.220

40FS91 6,920

40FQ920

38H0900T*

4- 7’4e

4- 8’46

28HQ036020

28VQ036020

40FS160

_

3- 3=46

3- 4=46

28HQ042030
28HQ048020

28VQ042030
28VQ048030

-

-

-

40FS160

-

3-10’/4

3-10%

28HQ042020
28HQ048020

28VQ042020
28VQ048020

-

-

-

40FS200

-

3-

7Va

3- 7%

28HQ060020

28VQ060020

40FS200.220

3-1IV,6

3-11V,6

-

-

-

-

-

40FS160

40FS,FO916

38H09000**

2-4=46

-

-

-

-

-

40FS200.220

40FS916,920

40FO920

38HQ9001**

28VH002/004

40FS075/1 20

40FS920EH

4- 7Ve

-

-

-

28VH002/004

40FS075/120

3-1IV

,6

*Total height may vary slightly depending on electric heater model used.

fLength dimension of assemblies in the horizontal position are same as

height dimension of units assembled for upflow airflow.

iAII height dimensions include 40FS filter section.

**For use with 38HQ227 and 234 only.

ttTotal height for 28QX coil with fan section and electric heater.

NOTE:

020.030

denotes dimensional variation within 28HQ/VQ models.

Refer to 28HQ/VQ literature for exact dimensions.

Table 3 — Installation and Usage Data (See Modular System Introduction, Page 3)

FAN

SECTION

COIL

(Draw-Thru Airflow)

ELECTRIC HEATER*

(Blow-Thru Airflow)

UNIT ASSEMBLY

POSITION

Upflow

Upflow,

Downflow

Horizontal

Upflow,

Downflow,

Horizontal

Upflow,

Downflow,

Horizontal

KW

Heating

Unit

Cooling

Unit

Heating and

Cooling Unit

208V

240 V

40FS075

28VH002

-

28VH002t

-

40FS920300EH

7.5

10.0

Fig. 2, 3

Fig. 4

except dow

Fig. 5

iflow —

40FS120

28VH004

Upflow

40FS920300EH

7.5

10.0

Fig. 2, 3

Fig. 4

Fig. 5

40FS160

-

28VQ036,

28VQ042

28HO036,

28HO042

28TQ042

40FS916300

6

- 18.8

8-25

Fig. 2, 3

Fig. 4

Fig. 5

40FS916320

3.75-15

5-20

40FS916500

7.5-22.5

10-30

40FO916

6-18.8

8-25

38HQ9000**

6-15

8-20

40FS200,
40FS220Í

280X036,

280X042

28VO042,
28VO048,

28V0060

28H0042,
28H0048,

28H0060,

280X036,

280X042

28TO048,

28T0060

40FS920300

7.5-22.5

10-30

40FS916320

3.75-15

5-20

40FS916500

7.5-22.5

10-30

40FQ920

7.5-22.5

10-30

38HQ9001**

7.5-18.8

10-25

*Electric heater for use with 208/230 V, 40FS units only. Refer to Electrical

Data and Wiring, Table 4, for fan section/electric heater usage and com­

plete electric heater model numbers.

fHorizontal application not recommended for Weathermaster IV system.
iModel 40FS220 not for use with 28QX coil.

**For use with 38HQ227 and 234 only.