Malfunctions

Possible causes

Remedy

Chap.

20

At low
temperatures:

If equipped with a
stop solenoid or
automatic electri-
cal shutdown sys-
tem (additional
equipment)

6.2.
Engine fires but
does not run.

Automatic
electrical shut-off
device
(optional extra)

6.3.
Starter motor does
not operate or en-
gine does not turn
over.

Starting speed below 400 min

-1

- Viscosity of oil too high.

- Battery charge too low.

Solenoid faulty and/or fault in
the electrical system.

Speed control lever not moved
far enough towards „START“.

Equipment not disengaged.

Fuel filter blocked.

One of the automatic shut-
down's monitoring elements
has initiated a stop signal.
(See also Chapter 6.4.)

Fault in the electrical system:
- Battery and/or other cables

incorrectly connected up.

- Cable connections loose and/or

oxidised.

- Battery faulty and/or flat.
- Starter motor faulty.
- Faulty relays, monitoring

element.

Change lubricating oil and add
oil of the correct viscosity class.

Check the battery, if necessary
contact a service station.

See workshop manual.

Move lever to „START“ position.

Disengage engine from equip-
ment if possible.

Renew fuel filter.

Localise the monitoring element
responsible and clear the fault,
or contact a HATZ service station.

Check electrical system and its
component. See also the work-
shop manual.

5.3.2.
4.1.1.

7.

4.2.1.

5.4.1.

7.