5.

Maintenance

Only carry out maintenance work with the engine switched off.
Observe all relevant laws and regulations governing the handling and disposal of used

oil, filters and cleaning agents.
Protect the starting key against unauthorised use.
On engines with an electric starter, disconnect the battery's negative terminal.
When maintenance work has been completed, check that all tools have been removed from
theengine and all protective guards fitted again.
Before starting the engine, ensure that there are no persons in the danger area close to the
engine or equipment.

5.1.

Maintenance chart

12

Maintenance interval

Maintenance work required

Chap.

Every 8 – 15 operating
hours, or before each
daily start-up

Check oil level.
Examine the lower section of the oilbath air
cleaner to ensure correct oil level and freedom
from contamination; change the oil if it contains
sludge.
On version with cyclone-type dust trap, empty the
dust collector.
Check combustion and cooling air intake zone.
Check air-cleaner maintenance indicator.
Check the water trap.

5.2.1.

4.1.2.

5.3.1.

5.3.1.
5.2.2.
5.2.3.
5.2.4.

Every 250
operating hours

Oilbath air cleaner maintenance.
Change engine oil.
Check and adjust valve clearances.
Clean cooling air area.
Check screw connections.
Clean mesh insert for exhaust.

5.3.1.
5.3.2.
5.3.3.
5.3.4.
5.3.5.
5.3.6.

Every 500
operating hours

Change fuel filter element.
Dry-type air cleaner maintenance.

5.4.1.
5.4.2.

Every 1000
operating hours

Clean the oil filter.

5.5.1.