Cleaning, Troubleshooting, Generator specifications – Winco WC10000VE/E User Manual
Page 13: Engine specifications
13
2015-00
60706-232
2.
Generator Maintenance - Any major generator
service, including the installation or replacement
of parts, should be performed only by a qualified
electrical service technician.
USE ONLY FACTORY
APPROVED REPAIR PARTS.
a. Bearing - The bearing used in these generators
is a heavy duty double sealed ball bearing.
They require no maintenance or lubrication.
b. Receptacles - Quality receptacles have been
utilized. If a receptacle should become cracked
or otherwise damaged, replace it. Using dam-
aged or cracked receptacles can be both dan-
gerous to the operator and destructive to the
equipment.
CLEANING
Remove dirt and debris with a cloth or brush. DO
NOT use high pressure spray to clean either the
engine or the generator. This high pressure spray
could contaminate the fuel system and the genera-
tor components.
1. Keep the air inlet screen on both the engine and
generator free of any dirt or debris to insure proper
cooling. At least yearly, remove the blower housing
on the engine and clean the chaff and dirt out of the
engine cooling fins and flywheel. Clean more often
if necessary. Failure to keep these areas clean may
cause overheating and permanent damage to the
unit.
2. Periodically clean muffler area to remove all
grass, dirt and combustible debris to prevent a fire.
3. On engine mufflers equipped with spark arrest-
ers, the spark arrester must be removed every 50
hours for cleaning and inspection. Replace if dam-
aged
TROUBLESHOOTING
PROBLEM (SYMPTOMS) POSSIBLE
CAUSES
———————————————————————
Won’t Start
*Low Oil Level.
*Fouled spark plug.
*Out of fuel.
*Start switch in Off position.
*Fuel valve turn off.
*Plugged fuel filter.
———————————————————————
Voltage too low
*Engine speed is too low.
*Generator overloaded.
*Defective stator.
*Defective rotor (field).
*Defective Capacitor.
———————————————————————
Circuit Breaker
*Defective load.
Trips
*Defective receptacle.
*Excessive Load.
———————————————————————
Voltage too high
*Engine speed is too high.
———————————————————————
Generator
*Overloaded.
overheating
*Insufficient ventilation.
———————————————————————
No output voltage
*Short in load (disconnect).
*Tripped or defective circuit
breaker.
*Broken or loose wire.
*Defective receptacle.
*No residual magnetism
(in generator).
*Defective stator.
*Defective rotor (field).
*Shorted capacitor.
*Shorted diodes on rotor.
*GFCI Receptacle tripped.
———————————————————————
GENERATOR SPECIFICATIONS
Generator manufacturer
MECC Alte Spa
Generator model number
S20W-130A
Part number
16346-004
Rotor resistance
5.67 Ohms
Stator resistance
0.145 Ohms
Cap winding resistance
1.31 Ohms
Capacitors
40 mF
Capacitor part number
16346-312
ENGINE SPECIFICATIONS
Engine manufacturer
Briggs & Stratton
Engine model number
356447
Type & Code
0006-G1
Spark plugs
491055
Air filter
394018
Air filter pre-cleaner
272490
Oil filter 6 cm long
492932
Oil filter 9 cm long
491056
Spark plug gap
0.030 in
Armature air gap
0.008 - 0.012 in
Intake valve clearance
0.004 - 0.006 in
Exhaust valve clearance
0.004 - 0.006 in
Oil capacity
46 - 48 oz.