60706-232
Output voltage should be checked periodically to
ensure continued proper operation of the generat-
ing plant and appliances. If the generator is not
equipped with a voltmeter, it can be checked with a
portable meter.
CONNECTING THE LOADS
APPLYING THE LOADS
Allow the engine to warm up for two or three minutes
before applying any load. This will allow the engine to
reach normal operating temperature and oil to circu-
late throughout the engine. A short warm-up time will
permit the engine to work more efficiently when the
load is applied and will reduce the wear in the engine,
extending its life.
Receptacles have been provided to allow loads to
be connected to the generator. The loads should be
added one at a time. If a large motor is being started;
or multiple motors are being started, they should be
started individually and the largest should be started
first.
CAUTION: EQUIPMENT OVERLOAD
Keep the generator load within the generator and
receptacle nameplate rating. Overloading may cause
damage to the generator and/or the loads .
Most electric tools and appliances will have the volt-
age and amperage requirements on their individual
nameplates. When in doubt, consult the manufacturer
or a local electrician. The nameplate amperage rating
for electric motors can be misleading. See “Starting
Electric Motors” in Unit Capabilities (page 4).
These engine-generator sets are inherently self regu-
lating based on engine speed. The engine governor
will automatically adjust itself to the load. No harm
to the generator will result if it is operated with no
load connected. Proper utilization of the receptacles
located on the control panel is necessary to prevent
damage to either the receptacles or the generator.
The generator is a limited source of electrical power,
therefore, pay special attention to the receptacle
and generator ratings. The nameplate rating can be
obtained through a single receptacle as long as the
receptacle amperage rating is not exceeded.
GROUNDING
All units must be grounded. Drive a 3/4 or 1” cop-
per pipe or rod into the ground close to the engine-
generator set. The pipe must penetrate moist earth.
Connect an approved ground clamp to the pipe.
Run a no. 10 Awg wire from clamp to the generator
ground lug on the receptacle panel. Do not connect
to a water pipe or to a ground used by a radio sys-
tem.The engine-generators covered in this manual
were designed primarily for portable use. If you
are connecting into a building wiring system that is
already grounded using the 14-60 4 wire plug, you
do not have to ground the unit.
WARNING: PERSONAL DANGER
DO NOT OPERATE THIS GENERATOR INDOORS.
The unit should be stored in a warm dry location.
During a power outage, move the unit outdoors to a
flat dry location such as a driveway or sidewalk
.
WIRING
Plug your tools such as drills, saws, blowers, sump
pump and other items to be powered directly into
the generator receptacles. Before plugging in all the
tools and cord sets, recheck the rating of the genera-
tor set. Be sure it can handle the intended load and
is compatible with the voltage, phase, and current
ratings. ‘Hard Wiring’ this unit directly into a tem-
porary construction site electrical system is
NOT A
SIMPLE DO-IT-YOURSELF JOB. For your safety,
all wiring must be done by a qualified electrician and
conform to the National Electric Code and com-
ply with all state and local codes and regulations.
Check with local authorities before proceeding.
WARNING: PERSONAL DANGER
A fully isolated, double pole double throw manual
transfer switch must be installed any time a genera-
tor is being connected to an existing distribution
system.
1. These engine generator sets are designed for
portable heavy duty commercial use. Receptacles
are provided on the control panel to permit 120 and
240 volt portable appliances and tools to be plugged
directly into them. Please note that the 3-wire 240
volt receptacle(s) on these units are designed to
power only 240 volt tools. There are two hot leads
and a ground wire, but no neutral connection, in the
3-wire 240 volt receptacle. A 4-wire receptacle (two
hot, one ground, and one neutral) has been provided
on the control panel for use in temporary power
applications requiring 120/240 volt power. Consult
a licensed electrician for wiring the TemPower plug
and connecting it as temporary service.