g. Remove oil filler plug and refill with new oil.

Refer to the table on page 5 for the proper

grade of oil based on your operating

temperature.

NOTE: This engine requires 46 to 48 ounces of oil

if it is completely drained. Use caution when refilling

the engine as some residual oil may have remained

in the engine. Always use the dipstick when filling

the engine with oil to prevent overfilling.

h. Replace filler plug.

I. Start the engine up and warm it up.

J. After warming up the engine, recheck the oil

level and refill as necessary to bring it to the

proper level. See page 5 for proper oil level.

2.

Checking the Oil Level: The oil level must al-

ways be checked before the engine is started. Take

care to remove any dirt or debris from around the

oil fill plug before removing. Be sure the oil level is

maintained. Fill to the “

FULL” mark on the dipstick.

3.

Dual Element Air Filter: Clean and or replace

foam pre-cleaner and air filter annually or every 100

hours. Service more often under dusty conditions.

WARNING: EQUIPMENT DAMAGE

Never start or run the engine with the air filter re-

moved

a. Loosen snaps (Ref “A”) and remove cover.

Ref “B”

b. Remove the nut (Ref “D”) and the retainer.

(Ref “E”)

c. Remove the air filter. (Ref “F”)

d. Remove the pre-cleaner (Ref “G”) from the air

filter.

e. To loosen debris, gently tap the air filter on a

hard surface. If the air filter is excessively dirty,

replace with a new filter.

Notice: Do not use pressurized air or solvents to

clean the filter. Pressurized air can damage the

filter and solvents will dissolve the filter.

f. Wash the pre-cleaner in liquid detergent and

water. Then allow it to thoroughly air dry.

DO NOT oil the pre-cleaner.

g. Install foam pre-cleaner to the air filter.

h. Install the air filter and secure with retainer and

nut

I Install and secure the cover.

4.

Spark Plug: Replace annually or every 100

hours of operation. Always replace with the same

spark plug that came in the engine and check gap

before installing. Spark plug gap is 0.030”. Poor

spark will also occur if spark plug wire does not fit

firmly on spark plug. If this happens, reform the

terminal to fit firmly on spark plug tip.

5.

Carbon Canister: Designed to collect, store,

and dispose of fuel vapors created in the fuel tank /

fuel system. The canister should last the life of the

unit as long as it stays dry.

GENERATOR CARE

Proper care and maintenance of the generator is

necessary to ensure a long trouble free life.

1.

Exercising The Generator - The generator

should be operated every three to four weeks. It

should be operated for a period of time sufficient

to warm the unit up and to dry out any moisture

that has accumulated in the windings. If left, this

moisture can cause corrosion in the winding. Fre-

quent operation of the engine generator set will also

insure that the set is operating properly should it be

needed in an emergency.

4

VanguardEngines.com

E

D

A

8

F

D

C

9

C

B

10

A

B

B

C

D

11

A

B

F

E

D

G

12

C

B

C

D

E

G

F