3041-00

60706-35

WARNING: PERSONAL INJURY

Lead acid batteries produce explosive hydrogen

gas when charging. Keep sparks, flames, and

burning cigarettes away from the battery. Ventilate

the area when charging or using the battery in an

enclosed space. Lead acid batteries contain sulfuric

acid, which causes severe burns. If acid contacts

eyes, skin or clothing, flush well with water. For con-

tact with eyes, get immediate medical attention.

BATTERY CHARGING

Units equipped with electric start have a small fly-

wheel charger built into the engine flywheel assem-

bly for recharging the starting battery. This flywheel

charger generates a small AC current that passes

through a diode assembly to produce a DC charg-

ing current of about 1 to 3 AMPS. This circuit is not

designed to be used as a battery charging circuit to

recharge dead batteries.

OPTIONAL DOLLY KIT

An optional dolly kit is available for this generator.

The dolly kit comes with instructions and parts list.

After installing the dolly kit, file the instructions and

parts list in the back of this manual for future refer-

ence.

OIL ALERT SYSTEM

This WINCO Industrial generator is equipped with a

low oil shutdown system. This engine uses a float

switch mounted inside the engine. If the oil level

drops below a certain point the low oil module on the

engine will shut it down. This low oil warning system

will automatically stop the engine before the oil level

reaches a critical danger point. This feature is de-

signed to prevent costly repairs and downtime.

CAUTION: EQUIPMENT DAMAGE

Allowing the engine to shutdown repeatedly on

low oil level may cause excessive wear which can

be cumulative.

CONSERV-R® IDLE CONTROL

The automatic Conserv-R

®

idle control is a gas sav-

ing, solid state system, designed to reduce engine

speed whenever the electrical load is removed from

the generator. Without a slow down control, the en-

gine would run at full speed at all times, regardless

of the electrical load.

CAUTION : EQUIPMENT DAMAGE

When using the L14-30 receptacle to power 120

volt loads the Conserv-R

®

control switch must be

left in the OFF position. Only one leg of the 240

volt circuit is monitored for load. Hence using

the individual 120 volt legs from this receptacle

will cause the Conserv-R

®

not to function prop-

erly.

With the automatic Conserv-R

®

control switch in the

“ON” position, the throttle control lever is electrically

released when the load is turned on so it in no way

interferes with the normal governor operation. When

the load is turned off, the idle magnet energizes and

reduces the engine speed. It does not cause incor-

rect operation of the carburetor or governor.

The automatic Conserv-R

®

control consists of a

solid state module mounted in the generator recep-

tacle box, a switch, resistor and an electromagnet

mounted on the engine near the throttle lever. The

automatic Conserv-R

®

control is only offered as a

factory installed feature. It is not available for field

installation.

With the automatic Conserv-R

®

switch in the “ON”

position, the system operates as follows:

1. After the engine has been started, and no electri-

cal load is applied, the solid state module senses

this condition and turns on the electromagnet. This

will pull and hold the throttle lever, closing the throttle

on the carburetor and reducing the engine speed.

. When a load is applied to the generator, the

current flow to the load is sensed by the solid state

control module and the electromagnet is turned off.

This releases the throttle arm, allowing the governor

to take over and open the throttle. The engine will

respond and come up to the governed speed (3600

rpm).

3. When the electrical load is turned off, the control

module will sense that there is no longer any current

flow and the automatic idle control will once again

energize the electromagnet, pulling and holding the

throttle. When the automatic Conserv-R

®

switch is in

the “OFF” position, the engine will run at full gov-

erned speed regardless of the generator load.