b. Receptacles - Quality receptacles have been

utilized. If a receptacle should become cracked

or otherwise damaged, replace it. Using dam-

aged or cracked receptacles can be both dan-

gerous to the operator and destructive to the

equipment.

CLEANING

Remove dirt and debris with a cloth or brush. DO

NOT use high pressure spray to clean either the

engine or the generator. This high pressure spray

could contaminate the fuel system and the genera-

tor components.

1. Keep the air inlet screen on both the engine and

generator free of any dirt or debris to insure proper

cooling. At least yearly, remove the blower housing

on the engine and clean the chaff and dirt out of the

engine cooling fins and flywheel. Clean more often

if necessary. Failure to keep these areas clean may

cause overheating and permanent damage to the

unit.

2. Periodically clean the muffler area to remove all

grass, dirt and combustible debris to prevent a fire.

3. On engine mufflers equipped with spark arrest-

ers, the spark arrester must be removed every 50

hours for cleaning and inspection.

Replace if damaged

TROUBLESHOOTING

PROBLEM (SYMPTOMS) POSSIBLE
CAUSES

———————————————————————

Won’t Start

*Low Oil Level.

*Fouled spark plug.

*Out of fuel.

*Start switch in Off position.

*Fuel valve turn off.

*Plugged fuel filter.

*Blown fuse in key switch

———————————————————————

Voltage too low

*Engine speed is too low.

*Generator overloaded.

*Defective stator.

*Defective rotor (field).

*Defective Capacitor.

———————————————————————

Circuit Breaker

*Defective load.

Trips

*Defective receptacle.

*Excessive Load.

———————————————————————

Voltage too high

*Engine speed is too high.

———————————————————————

Generator

*Overloaded.

overheating

*Insufficient ventilation.

———————————————————————

No output voltage

*Short in load (disconnect).

*Tripped or defective circuit

breaker.

*Broken or loose wire.

*Defective receptacle.

*No residual magnetism

(in generator).

*Defective stator.

*Defective rotor (field).

*Shorted capacitor.

*Shorted diodes on rotor.

*GFCI Receptacle tripped.

———————————————————————

SPECIFICATIONS

WC5000H/D

Generator manufacturer

WINCO Inc

Part number

15041-005

Rotor resistance

1.00 Ohms

Stator resistance G1-N.

0.18 Ohms

Stator resistance G3-N

0.35 Ohms

Cap winding resistance

0.54 Ohms

Capacitors

40.0 mF

Capacitor part number

15051-000

Engine manufacturer

HONDA

Engine model number

GX70R

Type

R1VW1

Spark plugs

BPR6ES (NGK)

Air filter

17211-ZE2-000

Spark plug gap

0.030 in

Oil capacity

1. qts.

SPECIFICATIONS

WC6000H/D & WC6000HE/D

Generator manufacturer

WINCO Inc

Part number

1553-006

Rotor resistance

11.5 Ohms

Stator resistance G1-N

0.10 Ohms

Stator resistance G3-N

0.18 Ohms

Cap winding resistance

0.80 Ohms

Capacitors

40.0 mF

Capacitor part number

15051-000

Engine manufacturer

HONDA

Engine model number

GX340

Type RECOIL

RT1VDE

ELECTRIC

RTVWE

Spark plugs

BPR6ES (NGK)

Air filter

17211-899-000

Spark plug gap

0.030 in

Oil capacity

1. qts.