B] am-50bae-ad – Twin Eagles AM-50BAE-AD User Manual
Page 8

8
U1VA6060209
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
3.4 A (5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
15 A
MAXIMUM FUSE SIZE
15 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*55 (25)
49 (22)
46 (21)
Reference without *marks
80
50 (23)
41 (19)
41 (19)
90
49 (22)
*34 (15)
33 (15)
100
42 (19)
34 (15)
32 (15)
SHAPE OF ICE
Column
φ20 x H27mm
ICE PRODUCTION PER CYCLE
0.65 lbs. (0.29 kg) 24 pcs.
APPROXIMATE STORAGE CAPACITY
27 lbs. (12.5 kg) [Bin Control Setting 22 lbs. (10.0 kg)]
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
238 (16.8)
227 (9.9)
WATER gal./24HR (gal./100 lbs.)
22.0 (63.9)
30.0 (53.7)
EXTERIOR DIMENSIONS (WxDxH)
14.9" x 22.6" x 31.5"
(378 x 575 x 800mm)
EXTERIOR FINISH
Stainless steel, Galvanized Steel (Rear)
WEIGHT
Net 88 lbs. ( 40 kg ), Shipping 99 lbs. (45 kg) without pallet
CONNECTIONS - ELECTRIC
Cord Connection
- WATER SUPPLY
Inlet 3/4" BSP
- DRAIN
Outlet HOSE I.D. φ15.5mm
CUBE CONTROL SYSTEM
Thermistor. Timer
HARVESTING CONTROL SYSTEM
Hot gas. Thermistor
ICE MAKING WATER CONTROL
Thermistor. Timer
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Thermostat
COMPRESSOR
Hermetic, Model QA51K13GAU6
CONDENSER
EVAPORATOR
Tin-plated copper tube on sheet and cups
REFRIGERANT CONTROL
Capillary Tube
REFRIGERANT CHARGE
R134a 4.2 oz. (120 g)
DESIGN PRESSURE
High 240 PSIG, Low 120 PSIG
P.C. BOARD CIRCUIT PROTECTION
N/A
COMPRESSOR PROTECTION
Auto-reset Overload Protector
ICE MAKER PROTECTION
N/A
ACCESSORIES - SUPPLIED
Ice Scoop; 3/8" male flare Water Inlet fitting
- REQUIRED
N/A
OPERATING CONDITIONS
VOLTAGE RANGE
104 - 127 V
AMBIENT TEMP.
45 - 100° F
WATER SUPPLY TEMP.
45 - 95° F
WATER SUPPLY PRESSURE
7 - 113 PSIG
AGENCY
UL OUTDOOR APPROVED, cUL
NSF
Air-cooled, Fin and tube type
We reserve the right to make changes in specifications and design without prior notice.
[b] AM-50BAE-AD